Instructions for the Installer
Permanent Connection
In the case of a permanent connection, it is necessary that you install a double pole
switch between the hob and the electricity supply (mains), with a minimum gap of 3
mm. between the switch contacts and of a type suitable for the required load in
compliance with the current electric regulations.
The switch must not break the yellow and green earth cable at any point.
Ensure that the hob supply cord does not come into contact with surfaces with
temperatures higher than 50 deg. C.
Replacement of the cable
The connection of the voltage cable to the appliance's terminal block is of type "Y".
This means that its replacement requires the specific equipment of a technician.
In this case, only cable types H05RR-F, H05 V2V2-F (T90) or H05 BB-F must be
used. The cable section must be suitable to the voltage and the working temperatu-
re.
The yellow/green earth wire must be approximately 2 cm. longer than the phase
wires.

Wiring diagram

1. TAPS IGNITOR SWITCHES
2. IGNITOR UNIT
3. LED POWER INDICATORS
18