Type of gas
Adjusted to natural gas: G20-20 mbar
Category and pressures
UK: II
20 mbar - 28/37 mbar
2H3+
Max. nominal load Q na H
Small sized burner=
Medium sized burner =
Large sized burner =
Total=
FSD
The unit features fully-secured gas
taps (thermo-fuse).
H
= Top calorific value
S
Q = Nominal load
ID. CE-048AU-0003
Ignition transformer= 50 HZ - 0,6 VA
Radio-noise reduction
This unit observes the current EEC-
directive on radio noise reduction.
This gas appliance is
marked in accordance with the gas
appliance Directive (90/396/CEE), the
low voltage directive (73/23/CEE) and
the EMC directive (89/336/CEE incl.
the agreed directive changes.
Cable type: 0,75 mm² HO5 V2V2-F

Technical data

:
The hob must be connected via an
S
1,0 kW x 1
external switch with a contact
1,9 kW x 2
gap of min. 3 mm (the main switch
2,7 kW x 1
may be used)
7,6 kW
Wiring
-approved and
12
240 V
1N + PE
N
L1
HO5V2V2-F
Blue and brown: 51 mm +/- 3 mm
Yellow/Green: 61 mm +/- 3 mm