Electrical Connection

Electrical Connection
The oven is designed to be connected to 230-240V~(50Hz) electricity supply.
The oven has an easily accessible terminal block which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to the electrical supply must comply to the specifications
given below.
For UK use only
Connection via
Cooker Control Circuit 2,5 mm²
It is necessary that you install a double pole switch between the oven and the electricity
supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type
suitable for the required load in compliance with the current regulations.
The switch must not break the yellow and green earth cable at any point.
After installation and connecting, the cable must be placed so that it cannot at any point
reach a temperature of more than 50°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the domestic installation can
support the load; and that the power supply is properly earthed.
The manufacturer declines any responsibility should these safety measures not be
carried out.

Installation

IMPORTANT
The new appliance may only be installed and connected by a qualified installation engineer.
Please comply with this instruction. If you do not, any damage resulting is not covered by
the warranty.
Safety information for the installer
• The set-up of the electrical installation is arranged so that the appliance can be isolated
from the mains with a minimum 3 mm all-pole contact separation.
Suitable isolation devices include, for example, circuit breakers, fuses (screw type fuses
are to be removed from the holder), RCDs and contactors.
• Anti-shock protection must be provided by the installation.
• The built-in unit must meet the stability requirements of DIN 68930.
Min. size Cable/flex
Cable/flex type
PVC/PVC twin and
earth
Fuse
min: 15 A
max: 20 A