Instructions For The Installer - Electrolux EOB 96000 User Information

Built-in electric oven with steam functionality
Table of Contents

Advertisement

40 electrolux

Instructions for the Installer

Installation and connection
must be done in compliance with
the regulations in force. Any
interventions must be carried out
when the appliance is switched
off. Only accredited engineers
may work on the appliance.
The manufacturer disclaims any
liability if the safety measures
are not observed.
Connecting to the electrical supply
Before connecting to the electrical supply,
please make sure:
-
The fuse and the domestic electrical
installation must be designed for the
max. load of the appliance (see rating
plate).
-
The domestic electrical installation
must be equipped with a proper earth
connection in accordance with the
regulations in force.
-
The socket or the multi-pole off switch
must be easy to access after the
appliance has been installed.
The appliance is supplied with the plug at-
tached. The mains cable and plug as sup-
plied are to be connected to a shockproof
socket (230 V~, 50 Hz). The shockproof
socket must be installed in accordance with
the regulations.
The following types of mains cable are suit-
able, taking the necessary rated cross sec-
tion into account: H07 RN-F, H05 RN-F, H05
RR-F, H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
If the appliance is connected without a plug,
or if the plug is not accessible, a multi-pole
off switch (e.g. fuses, circuit breaker) with a
minimum gap of 3 mm between the con-
tacts must be installed between the appli-
ance and mains cable. The switch must not
interrupt the earth wire at any point. The yel-
low-green earth wire should be 2-3 cm longer
than all other cables.
The connection cable must in any case be
laid out so that at no point does it reach
50°C (over room temperature).
After the connection has been carried out,
the heating elements must be tested by be-
ing operated for about 3 minutes.
Terminal block
The oven is fitted with an easily accessible
terminal block which is designed to operate
with a single-phase power supply of 230 V.
Letter L
-
Letter N
-
or E -
Earth terminal
Live terminal
Neutral terminal