Vue™ 6.1 Maintenance Guide
Symptom(s)
1 or more LED's are not
illuminating
1 or more LED's are producing
very low output
Breaker/Fuse keeps blowing
Device has no power
Fixture is not responding to DMX
Loss of signal
Stand alone operation problem
The motor is not rotating
If you still have a problem after trying the above solutions, please contact CHAUVET Technical
Support at the location on the next page.
Vue™ 6.1 User Manual
Clean the fixture regularly to avoid any such failure. This fixture is convection
cooled, which means that if the surface is kept clean and free of debris, then
proper cooling will be allowed to occur
An LED may have failed, resulting in an open circuit. In this event, all of the
red, green, or blue in a single module will no longer illuminate. This does not
mean that all of the LEDs have failed, but the circuit is wired in series.
An LED may have failed, resulting in a short circuit. In this event, only the
single LED which has failed will no longer function. This does not mean that all
of the LEDs have failed, but the circuit is wired in series.
-Note: In the event of LED failure, a replacement LED PCB assembly may be
purchased directly from CHAUVET
Check that the lens assembly is installed properly. If the lens assembly is not
aligned properly over the LEDs, then they will not project fully
-See section on Lens Assembly Installation
-Note: In the event of LED failure, a replacement LED PCB assembly may be
purchased directly from CHAUVET
Check total load placed on the electrical circuit
Check for a short in the electrical wiring: internal and/or external
Check device's fuse (internal)
Check for power on Mains
-Note: In the event of autoswitching transformer failure, the unit can be sent in
for repair; however, a replacement part can be ordered directly from
CHAUVET
Check Control Panel settings for correct addressing
Check DMX cables
Check polarity switch settings on the controller
Check cable connections
Call service technician
See page #11 for proper settings for DMX operation
-Note: In the event of Master PCB failure, a replacement PCB can be ordered
directly from CHAUVET
Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables or black lights
See page #11 for proper settings for standalone operation
This fixture uses a separate channel to operate the motor rotation. Try
operating the fixture in standalone mode to determine if the problem is DMX
related. If the motor still does not rotate, then it may need to be replaced, or
the motor driver IC or the Master PCB may need to be replaced.
-Note: In the event of motor failure, a replacement motor can be ordered
directly from CHAUVET
-Note: In the event of Master PCB failure, a replacement PCB can be ordered
directly from CHAUVET
15
Possible Solution(s)
Part#: P222-VIVDLED
Part#: P222-VIVDLED
Part#: P140-VIELTR
Part#: P170-VUEIVMP
Part#: P110-VUEMTR
Part#: P170-VUEIVMP