List of trouble log
Note: "nnn" of toggle article number is a generation frequency of the error.
Type
(Remote commander)
Rebooting emergence
(Rebooting emergence
Test key2 (R)
factor)
Serial communications
(MTK communication
Test key3 (t)
error factor)
MTK power control
(Power ON/OFF error
Test key2 (r)
factor)
Test key
Toggle article
number
2Annn
2Bnnn
2Cnnn
2Dnnn
2Ennn
2Fnnn
2Gnnn
3Annn
3Bnnn
3Cnnn
3Dnnn
3Ennn
3Fnnn
4Annn
4Bnnn
4Cnnn
4Dnnn
4Ennn
4Fnnn
4Gnnn
4Hnnn
It was not possible to communicate with MTK fi ve seconds more continu-
ously
Compulsion power off demand was received from MTK
Only MTK reset it
(Distination, model and region for are the disagreements)
Fails in the start of MTK
Fails in the switch of the input mode of MTK
Input mode of MTK changed without permission
Reacts to the key notifi cation no though the communication with MTK is
alive
It was not possible to communicate with MTK with 48ms
A non-standard packet length was received (Excluding 16 bytes)
Checksum NG
Type of the communication header is NG
PEQ data reading operation (8032tDVDLIB) terminated abnormally
PEQ data writing operation (DVDLIBt8032) terminated abnormally
Fails in AC ON Initial
Fails in power on of MTK
Initialization response of CDM is abnormal
CDM mechanism error notifi cation is received
Input mode is NG MTK is started
MTK input mode switch at time fails usually
Fails in power off of MTK
Fails in power off of CDM