Sensor Table

Memory ECC
Sensor
Sensor Name
Sensor Type
No.
0xD1
CPU1_ECC1
Memory ECC Sensor
0xD2
CPU1_ECC2
OEM Memory ECC Sensor
(For Intel DP platform only
-- ASUS Z8 series server
MB; -E6 server system)
0xD3
CPU2_ECC1
Memory ECC Sensor
0xD4
CPU2_ECC2
OEM Memory ECC Sensor
(For Intel DP platform only
-- ASUS Z8 series server
MB; -E6 server system)
ASUS ASMB6-iKVM
Sensor Type
Sensor Value or Event Type
code
0x0C
Discrete(0x6F)
0x01: Correctable ECC
0x02: Uncorrectable ECC
0x40: Presence detected
0xC1
Discrete(0x6F)
0x01: Read ECC error
0x02: ECC Error occurred on a scrub
0x04: Write Parity Error
0x08: Error in Redundant memory
0x10: Sparing Error
0x20: Memory access out of Range
0x40: Address Parity Error
0x80: Byte Enable Parity
0x0C
Discrete(0x6F)
0x01: Correctable ECC
0x02: Uncorrectable ECC
0x40: Presence detected
0xC1
Discrete(0x6F)
0x01: Read ECC error
0x02: ECC Error occurred on a scrub
0x04: Write Parity Error
0x08: Error in Redundant memory
0x10: Sparing Error
0x20: Memory access out of Range
0x40: Address Parity Error
0x80: Byte Enable Parity
Event Data 3
0x00: DIMM_A1, 0x01: DIMM_A2,
0x02: DIMM_A3, 0x03:DIMM_A4,
0x04: DIMM_B1, 0x05: DIMM_B2,
0x06: DIMM_B3, 0x07: DIMM_B4,
0x08: DIMM_C1, 0x09: DIMM_C2,
0x0A: DIMM_C3, 0x0B: DIMM_C4,
0x0C: DIMM_D1, 0x0D: DIMM_D2,
0x0E: DIMM_D3, 0x0F: DIMM_D4
0x00: DIMM_A1, 0x01: DIMM_A2,
0x02: DIMM_A3, 0x03:DIMM_A4,
0x04: DIMM_B1, 0x05: DIMM_B2,
0x06: DIMM_B3, 0x07: DIMM_B4,
0x08: DIMM_C1, 0x09: DIMM_C2,
0x0A: DIMM_C3, 0x0B: DIMM_C4,
0x0C: DIMM_D1, 0x0D: DIMM_D2,
0x0E: DIMM_D3, 0x0F: DIMM_D4
0x00: DIMM_D1, 0x01: DIMM_D2,
0x02: DIMM_D3, 0x03: DIMM_D4,
0x04: DIMM_E1, 0x05:DIMM_E2,
0x06: DIMM_E3, 0x07: DIMM_E4,
0x08: DIMM_F1, 0x09: DIMM_F2,
0x0A: DIMM_F3, 0x0B: DIMM_F4,
0x0C: DIMM_G1, 0x0D: DIMM_G2,
0x0E: DIMM_G3, 0x0F: DMM_G4,
0x10: DIMM_H1, 0x11: DIMM_H2,
0x12: DIMM_H3, 0x13: DIMM_H4,
0x14: DIMM_C1, 0x15: DIMM_C2,
0x16: DIMM_C3, 0x17: DIMM_C4
0x00: DIMM_D1, 0x01: DIMM_D2,
0x02: DIMM_D3, 0x03: DIMM_D4,
0x04: DIMM_E1, 0x05:DIMM_E2,
0x06: DIMM_E3, 0x07: DIMM_E4,
0x08: DIMM_F1, 0x09: DIMM_F2,
0x0A: DIMM_F3, 0x0B: DIMM_F4,
0x0C: DIMM_G1, 0x0D: DIMM_G2,
0x0E: DIMM_G3, 0x0F: DMM_G4,
0x10: DIMM_H1, 0x11: DIMM_H2,
0x12: DIMM_H3, 0x13: DIMM_H4,
0x14: DIMM_C1, 0x15: DIMM_C2,
0x16: DIMM_C3, 0x17: DIMM_C4