Download Print this page

GE RHM 04 Overwiew And Specifications page 5

Measurement & control versatile coriolis mass flowmeter with fast response times for very high pressure applications

Advertisement

Pressure Rating RHM 04
The maximum pressure (pmax) of a sensor is determined by its weakest part. The weakest part can be the measuring
loops (pmax indicated below) or the construction type (pmax indicated in the Basic Order Code section, last page) or the
selected flanges / fittings (for pmax please see respective standard).
pmax of P1 measuring loops, standard
M0 standard material - 1.4539 (904 L)
OD x WT 4.5 x 0.3 mm (0.18 x 0.012 in)
bar
°C
170
50
150
120
120
210
100
350
pmax of P2 measuring loops
M0 standard material - 1.4539 (904 L)
OD x WT 4.5 x 0.5 mm (0.18 x 0.02 in)
bar
°C
295
50
250
120
200
210
170
350
psi
°F
2466
122
2176
248
1740
410
1450
662
psi
°F
4279
122
3626
248
2901
410
2466
662
pmax of P1 measuring loops
M3 optional material - 2.4602 (Alloy C22)
OD x WT 4.5 x 0.3 mm (0.18 x 0.012 in)
bar
°C
215
50
190
120
153
210
128
350
pmax of PH measuring loops
HP optional material - HP160
OD x WT 4.5 x 0.9 mm (0.18 x 0.035 in)
bar
°C
1067
20
900
50
870
120
pmax of P1 measuring loops*
M1 optional material - 1.4571 (316 Ti)
OD x WT 4.5 x 0.3 mm (0.18 x 0.012 in)
bar
°C
156
50
*Only for T3 temperature rating
psi
°F
3118
122
2756
248
2219
410
1856
662
psi
°F
15476
68
13053
122
12618
248
psi
°F
2263
122
5

Advertisement