Download Print this page

Philips IP65 Installation And User Manual page 9

Luminaires
Hide thumbs Also See for IP65:

Advertisement

SL STRIP 400 TW LED Luminaires
Installation & User's Manual
Connecting SL STRIP 400 TW LED Luminaires to AC Power
If the unit is supplied with an AC input cable without an input connector installed. The input connector is a user-
supplied accessory.
Table 2 describes how to connect power to your SL STRIP 400 TW LED Luminaire. Field wiring of the SL STRIP
400 TW LED Luminaire is straight forward. A total of 3 wires/conductors is supplied from the unit. The following
wiring scheme is used:
Table 2: SL STRIP 400 TW LED Luminaire (IP65 Rated Models) AC Input Connections
Wire Color
Purpose
Brown
Main / Line (100 to 240VAC)
Blue
Neutral
Green/Yellow
Ground (Earth)
Bottom of Unit
AC Output
AC Input
Figure 3: SL STRIP 400 TW LED Luminaire AC Input & Output Connections
CAUTION: In the event the AC input cable of this luminaire is damaged, it must be replaced, by the user, with an
approved cable through an Authorized Showline Dealer or Service Center.