Specification; Indoor Unit - Electrolux EL-KFR26G/TN2Y-A Technical & Service Manual

A/b series multi split type, heat pump air conditioners
Table of Contents

Advertisement

2 Specification

2.1 Indoor unit

Power supply
Capacity
Cooling
Input
Rated current
Capacity
Heating
Input
Rated current
Model
Brand
Indoor fan motor
Input
Capacitor
Speed(hi/mi/lo)
a.Number of rows
b.Tube pitch(a)x row pitch(b)
c.Fin spacing
Indoor coil
d.Fin type (code)
e.Tube outside dia.and type
f.Coil length x height x width
g.Number of circuits
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Dimension (W*H*D)
Indoor unit
Packing
Net/Gross weight
Design pressure(Hi/Lo)
Liquid side/ Gas side
Refrigerant piping
Max. refrigerant pipe length
Max. difference in level
Connection wiring
Plug type
Thermostat type
Operation temp
Ambient temp
Application area
Model
(W*H*D)
EL-KFR26G/TN2Y-A(B)
Ph-V-Hz
1, 220-240V~,50Hz
Btu/h
9000
W
36.5
A
0.17
Btu/h
10000
W
36.5
A
0.17
RPG13H
Welling
W
36.5
uF
1.2
r/min
1180/1080/1000
mm
21x13.37
mm
1.3
Hydrophilic aluminium
mm
φ7 INNEGROOVE TUBE
mm
578X252X26.74
m3/h
500/460/410
dB(A)
40.5/37.4/34.6
mm
750×250×214(210)
mm
837X340X295
Kg
9/11
MPa
2.8/1.2
mm
Ф6.35/Ф9.53
m
m
10A
Electronic control
17-30
18-45
m2
14-21
Page 4 of 33
EL-KFR36G/TN
1, 220-240V~,50Hz
2
Hydr0philiC aluminium
φ7, innergroove tube
2
10
5
No
Electronic control
Y-A(B)
2
12000
51.5
0.24
13000
51.5
0.24
RPG20D
WELLING
51.5
1.5
1250/1000/800
2
21×13.37
1.3
635×315×27.34
2
680/520/420
42.0/35.0/30.0
815x282x217
915x360x295
10.5kg/12kg
2.8/1.2
Ф6.35/Ф12.7
10
5
No
16A
17-30
18-45
18-26

Hide quick links: