Electrical Connection - Electrolux ESF 66060 User Manual

Electrolux dishwasher
Table of Contents

Advertisement

20 electrolux
Warning!
• The mains cable is in the double-
walled inlet hose. Do not immerse
the water inlet hose or the safety
valve in water.
• Do not attempt to shorten the inlet
hose.
• If the water inlet hose or the safety
valve is damaged, immediately turn
off the power and remove the mains
plug from the mains socket.
• Only a qualified Service Engineer can
replace the water inlet hose with
safety valve.
Warning!
Dangerous voltage
In order to pass the safety valve
through the kitchen cabinets, an open-
ing of at least 45mm x 90mm is nee-
ded.
Water drain hose
The highest point of the drain hose must be
no more than 60 cm from the floor and
must have a continuous fall to the plumbing
connection.
The drain hose can be lengthened using
additional lengths and connectors. These
must be purchased from Electrolux Spare
Parts. The extension length must not ex-
ceed 2 metres.
The drain hose must be free of kinks and
obstructions.
Remove the sink plug when the appliance
drains the water to prevent that the water
goes back into the appliance.

ELECTRICAL CONNECTION

Warning! Safety standards require the
appliance to be earthed.
Prior to using the appliance for the first
time, ensure that the rated voltage and
type of supply on the rating plate
If you connect the water drain hose to a
trap spigot under the sink, remove the plas-
tic membrane. If you do not remove the
membrane, remaining food can cause a
blockage in the drain hose spigot.
The appliance has a security feature to
prevent dirty water going back into the
appliance. If, the spigot of the sink has
a 'non-return valve', this valve can
cause the appliance to drain incorrect-
ly. Remove the non-return valve.
Caution! Make sure that the water
couplings are tight to prevent water
leakage.
Ensure that hoses are not crushed or
kinked under or behind the appliance.
Once connected the inlet hose to the
water tap, turn the tap on and check
that there are no leaks.
match that of the supply where the ap-
pliance is to be installed.
The fuse rating is also to be found on
the rating plate.