  • Page 1 OWNER’S MANUAL PP500AC HIGH SURGE POWER INVERTER WHISTLER ENHANCED DRIVING TOOLS...
  • Page 2 Included in the WHISTLER line is a special selection of products we call “Enhanced Driving Tools.” These products range from portable jump start systems to high intensity flashlights to radar detectors and are...
  • Page 3 This lower power requirement is referred to as the “continuous load.” In order to ensure that the capacity of your WHISTLER 500 is sufficient to meet the required start up load, you must first determine the power consumption of the equipment or appliance you plan to operate.
  • Page 4 ON (I), OFF (0), and ON (I) again in quick succession. If this procedure is unsuccessful, it is likely that the WHISTLER 500 does not have the required capacity to operate the equipment or appliance in question.
  • Page 5 OWNER’S MANUAL Making The Connection. 1. Make certain that the WHISTLER 500 rocker switch is in the OFF (0) position. 2. Connect the cables to the power input terminals at the rear of the inverter and tighten the screws to make a secure connection. Do not over tighten these screws.
  • Page 6 You’ll Get A Charge Out Of This. (Or Maybe Not). Using the WHISTLER 500 to recharge units designed to charge such portable equipment as power tools, flashlights, video cameras and laptop computers may cause damage to the inverter or to the charging unit.
  • Page 7 More than one filter may be required. (These filters are available at most electronic supply stores including Radio Shack. See Radio Shack Part # 273-105). 6. Ground the WHISTLER 500 using an 8 AWG grounding wire in as short a length as possible. Note: •...
  • Page 8 Automatic Shut Down Safety Features. The LED Indicator light (See “Front View” Illustration, Page 3) will turn from GREEN to RED and the WHISTLER 500 will turn itself off automati- cally when: 1. The power input from the battery drops to 10.5 volts. (When the power input drops to 11 volts, an alarm will sound for an extended period);...
  • Page 9 OWNER’S MANUAL Note: • The WHISTLER 500 is equipped with a cooling fan which is designed to run continuously while the inverter is operating. Automatic shut down caused by excess circuit temperatures occurs when the cooling fan is unable to maintain the design parameters for safe operation of the inverter.
  • Page 10 For You Technical Types. I. Basic Operating Principles. The WHISTLER 500 works in two stages. During the first stage, the DC to DC converter increases the DC input voltage from the power source (e.g a 12 volt battery) to 145 volts DC. In the second stage, the high voltage DC is converted to 110 volts (60 Hz AC) using advanced power MOSFET transistors in a full bridge configuration.
  • Page 11 Never attempt to operate the WHISTLER 500 from any power source other than a 12 volt battery. • The WHISTLER 500 is designed to be connected to the power source with the supplied cables or with #4 wire. When utilizing the cables, do not attempt to modify them.
  • Page 12: Troubleshooting

    WHISTLER PP500AC Troubleshooting PROBLEM: No Output Voltage Problem Solution Poor contact With battery Clean terminals thoroughly. terminals. Battery voltage below Recharge or replace battery. 10.5 volts. Equipment being operated Use a higher capacity inverter draws too much power. or do not use this equipment.
  • Page 13 OWNER’S MANUAL PROBLEM: Low Battery Alarm On All The Time Problem Solution Input voltage below 10.5 volts. Keep input voltage above 10.5 volts to maintain regulation. Poor or weak battery condition. Replace battery. Inadequate power being Use lower gauge wire. delivered to the inverter or See “Wire Cable Gauges”...
  • Page 14 All express or implied warranties for this product are limited to one year. Whistler is not liable for damages of any type arising from the use, misuse, or operation of this product.
  • Page 15 If you have questions conCerning the operation of this Whistler product please Caft Customer technical service: 1-800-531-0004 Hours: Monday Friday 9:00 am 5:00 pm EST WHISTLER 500 WATT INVERTER SPECIFICATIONS Maximum Continuous Power 500 Watts Maximum Surge Capability (Peak Power)