PROBLEM
The air-conditioner
does not work
The air-conditioner
functions for only
short periods as
safety has been
enabled.
The function OK
signal lamp flashes.
General switch
keeps activating
The appliance works
but does not cool
the environment
sufficiently
30
CAUSE
• pilot lamp
is OFF
- power failure
- plug is disconnected
• Memo Control signal lamp is flashing
- three minutes have not elapsed since unit
last switched off
• Signal lamp flashing
- air-conditioning function: room tempera-
ture below set level
• Exhaust hose is blocked
• Exhaust hose is bent
• Condensator fan is blocked
• There are discrepancies in the control card
• Window open
• Source of heat in room (heater, lamp, etc.) or
room is overcrowded
• Exhaust hose is disconnected
• Thermostat regulated too high
• Air filter clogged
• The capacity of the conditioner is not ad-
equate for the size of the room
REMEDY
• wait
• connect plug
• wait three minutes
• turn thermostat cursor slowly to maxi-
mum cold
• check whether discharge of air to
outside is obstructed in any way.
Press the ON/OFF pushbutton to start
up the unit again.
• straighten it
• contact Service Centre
• contact Service Centre
• switch off appliance and contact Serv-
ice Centre
• close the window
• remove heat source
• reconnect tube
• lower thermostat setting
• clean filter