RECEPTACLES
CAUTION
m
_BI
_e]mE_,_i_D]E_lm._mgm
12 Volt DC,
I 0 Amp
Receptacle
ThTs receptacle _llows you to recharge _ 12%1=
automo:fve
or utfliv/style
storage battery wfth :he bakery
charge cables provided (Figure 8),
ThTs receptacle can no= recharge 6Volt bakeries and can
no: be used to crank an e_gine h_ving a discharged bakery,
See the section "Charging a Batter)/' (page 9) before
a_empting
to recharge a bakery,
120 Volt AC, 20 Amp,
Duplex
Receptacle
Eachreceptacle (Figure9) is protected agains: overload by
a 20 Amp push-to-reset cTrcui:breaker.
Use each recep_cle to operate 120%1=AC, single-phase,
60 Hz electrTcalloads requiring up to 2,400 wa_ (2.4 kVV)
a: 20Amps of curren:. Use cord se=sthat are ra:ed for
125Volt AC loads at 20 Amps (or grea=er).
120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA I-5-30 plug with this recep_cle,
Connec: a
3-wira cord se: rated for 125VoltAC
loads at 30 Amps to
the plug (Figure 10).
3-Wire
Cord Se:
NEMA
L5-30
A Neu:ral
120V
Hot
Ground (Green)
Use :hfs receptacle to opera:e 120 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 wa_s (3,6 kW) of pov_er
a: 30 Amps,The outle: is protected
by a 30 Amp
push-:o-reset
circui: breaker,