Mounting
Caution: In order to avoid a hazard this
appliance must be installed according to
these instructions for installation, also
complying with Gas Safety (installation
& use) Regulation
The hob unit can be mounted in any type
of kitchen with a table surface whose
thickness is between 28 mm and 40 mm.
Headroom
The distance to any shelves or tops of a
cabinet under the hob is to be at least 55
mm.
Fixing
Screw the fixing brackets out to such an
extent that they can be turned in under
the table top. Tighten the brackets on to
the table top with an ordinary
screwdriver.
Cut-out measurements
One rectangular hole is sawn out for the
hob combination chosen.
The depth of the cut-out for any unit is:
490 mm
Length of hole = sum of all units`
externally measured lenght, less 20 mm.
Mounting of Reinforcement
Beams
A reinforcement Beam, with supporting
flanges at each end, is included with each
two-burner unit. For unit combinations, a
reinforcement beam must be used
between each unit.
Minimum distance
Minimum distance to
wall (non flammable
to wall:
150 mm
material): 50 mm
Reinforcement
beams
12
The wok-unit has a special pan support
which enables use of a wok pot with
curved bottom.
When using cooking utensils with a
flat bottom the diameter of the utensils
must not be less than 26 cm.