Connecting To The Mains; Build-In Model; Technical Data - Electrolux EMS2485 Instruction Book

Hide thumbs Also See for EMS2485:
Table of Contents

Advertisement

EMS 2485
The plug moulded on to the lead incorporates a
fuse. For replacement, use a 16 Amp BS1362 fuse.
Only ASTA or BSI approved fuses should be used.
The plug must not be used if the fuse cover/carrier
is lost. The cover/carrier is indicated by the coloured
insert at the base of the plug.
A replacement cover/carrier is indicated by the
coloured insert at the base of the plug.
A replacement cover/carrier must be obtained from
your local Electrolux Service Centre.
This appliance complies with E.E.C. directive No.
87/308 of 2.6.87 relative to radio interference sup-
pression.

Build-in model

To install the appliance in a kitchen cabinet, use the
appropriate mounting frame. Note the relevant in-
structions for installation and connection. When
building in to a high cabinet, you may use the lift-
door. Note the relevant information for installation
and connection given in the operating instructions
of the lift door.
Attention !
Never operate the microwave oven with the lift door
closed. Such operation would damage your appli-
ance and invalidate the guarantee.

Technical data

Building in kit
Overall dimension
Cavity
Volume
BF 246
Width
540 mm
Depth
416 mm
Height
316 mm
Width
350 mm
Depth
351 mm
Height
210 mm
24 l

Connecting to the mains

The oven is delivered with the power cord and a plug
for 230 V, 50Hz, earthed socket outlet.
Earth protection minimizes the risks should a short-
circuit occur. Check to ensure the voltage of the
oven matches the supply.
N.B. If the oven is connected to the socket via an
extension cord, make sure the cord is earthed.
Thi
s applianc
!
nonearth protected power supply. Contact
an electrician if you are uncertain regarding
electricial connection of the oven or provision
of
earth
This appliance must be earthed. If this
appliance is fitted with a non-rewirable plug
for which your socket is unsuitable, the plug
should be cut off and the appropriate plug
fitted. If it is necessary to change the fuse in
a nonrewirable plug, the fuse cover must be
refitted. If the fuse cover is lost or damaged,
the plug must not be used until a replacement
is obtained.
Connect to a plug socket with protective earth
contact and fused with a 16 A-L automatic device or
16 A slow-blowing fuse. When the oven is installed,
there must be a possibility of disconnecting it from
mains with a contact break of at least 3 mm on all
poles.
A suitable size of LS-switch, or a melting or fly-out
fuse, are suitable contact-breakers.
Power source
Fuse
Power consumption
(microwave + grill)
Power Output
Grill
Weight
32
e must not be used on a
protection
of
the
230 V, 50 Hz
16A
2750W
900W
1250W
19 kg
supply.