Instructions for the Installer

Engineers technical data

Overall dimensions
Width:
Depth:
Cut out dimensions
Width:
Depth:
Supply connections
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
NOMINAL THERMAL
POWER kW
NOMINAL FLOW
RATE m
NOZZLE REFERENCE
NOMINAL THERMAL
POWER kW
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
Semi-rapid
Rapid
Aeration adjustment none
6
580 mm.
510 mm.
550 mm.
470 mm.
BURNER
RAPID
(large)
POSITION
MAX
2.9
3
/h
0.276
119
1/100 mm
2.7
g/h
195
86
1/100 mm
28
32
42
Ignition HT Spark
Spark Generator
Spark Gap
Semi-rapid Burner
Heat Input
Rapid Burner
Heat Input
Auxiliary Burner
Heat Input
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
0.75
1.9
0.45
1.0
0.062
0.181
0.043
0.095
Adjust.
96
Adjust.
70
0.75
1.9
0.45
1.0
46.8
137
32.4
72
40
71
32
50
APPLIANCE CLASS:
APPLIANCE CATEGORY:
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
Ispra Control's BF 50046
230-240V 0.6 YA T 120
1.9 kW (6483 BTU/HR)
2.9 kW Natural Gas (9895 BTU/HR)
2.7 kW L.P.G. (9212 BTU/HR)
1.0 kW (3412 BTU/HR)
(small)
MIN
0.33
0.031
Adjust.
0.33
23.8
28
3
II2H3+
Fixed