Troubleshooting - TOTALINE P474-0140 Owner's Manual

Non-programmable digital heat pump thermostat
Table of Contents

Advertisement

OWNER'S MANUAL

TroubleShooting

SYMPTOM: The slide switches on the thermostat
TOTALINE
72
are very difficult to move.
Heat Off Cool
Fan On FanA uto
CAUSE: The backplate of the thermostat is
screwed too tightly into a wall that is not
perfectly flat.
REMEDY: Loosen the screws holding the
thermostat into the wall.
SYMPTOM: The Air Conditioning does not
TOTALINE
72
attempt to turn on.
Heat Off Cool
Fan On FanA uto
CAUSE: The cooling setpoint is set too
high, the Mode Switch is not set for
Cool, the batteries are too weak, or the
Aux. Heat Switch is set for Emergency.
REMEDY: Consult the Normal Operation
section in this manual to:
Lower the cooling setpoint (Page 6)
Correct the Mode Switch position (Page 6)
Replace the batteries (Page 10)
Adjust the Aux Switch to Normal (page 7)
SYMPTOM: The fan does not turn on even though
TOTALINE
72
the compressor has energized.
Heat Off Cool
Fan On FanA uto
CAUSE: The Fan Switch is not completely in the
On or Auto position.
REMEDY: Slide the Fan Switch firmly into the On
or Auto position.
MODEL P474-0140
Page 19