Appendix; General Troubleshooting - Chauvet Slim Par Pro TRI User Manual

Table of Contents

Advertisement

5. A
PPENDIX

General Troubleshooting

5. Appendix

S
YMPTOM
· Excessive circuit load
Breaker/Fuse
keeps blowing
· Short circuit along the power
wires
· No power
Device does not
power up
· Loose power cord
· Wrong DMX addressing
· Damaged DMX cables
Fixture is not
· Wrong polarity settings on the
controller
responding to DMX
· Loose DMX cables
· Faulty DMX interface
· Faulty Main PCB
· Non DMX cables
· Bouncing signals
· Long cable / Low level signal
Loss of signal
· Too many fixtures
· Interference from AC wires
If you still have a problem after trying the above solutions, please contact CHAUVET®
Technical Support.
P
C
(
)
OSSIBLE
AUSE
S
· Check total load placed on the
· Check for a short in the electrical
· Check for power on Mains.
· Check power cord
· Check Control Panel and unit
· Check DMX cables
· Check polarity switch settings on
· Check cable connections
· Replace DMX input
· Replace Main PCB
· Use only DMX compatible cables
· Install terminator as suggested.
· Install amplifier right after fixture
· Install an optically coupled DMX
· Keep DMX cables separated from
15
P
A
(
)
OSSIBLE
CTION
S
electrical circuit.
wiring (internal and/or external).
addressing
the controller
with strong signal.
splitter after unit #32.
power cables or black lights.
6/24/2013 11:35 AM

Advertisement

Table of Contents
loading

Table of Contents