  • Page 1: User Manual

    LED Techno Strobe™ ST-3000LED User Manual CHAUVET, 3000 N 29 Ct, Hollywood, FL 33020 U.S.A (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.com 2009-12-10 14:04...
  • Page 2: Table Of Contents

    UPPORT ©CHAUVET, 2006, All Rights Reserved Information and specifications in this User Manual are subject to change without notice. CHAUVET assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. ST-3000LED User Manual ... 9 ...
  • Page 3: Before You Begin

    World Wide Web ST-3000LED User Manual Save the carton and all packing If you should require sending any items back to CHAUVET, call CHAUVET for a (RMA) Return Merchandise Authorization number. The factory will not allow any shipments without an RMA.
  • Page 4: Important Safety Information

    If you have any questions about how to operate the fixture safely, please contact CHAUVET. P r o t e c t i o n a g a i n s t E l e c t r i c S h o c k Always disconnect from AC power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source.
  • Page 5: Introduction

    CONTROL MODES & OPTIONS (Rows) For a detailed view of DMX values turn to the Appendix section in this manual. Control mode parameters are set by DMX values in Channel # 1. ST-3000LED User Manual UMMARY Strobe 000~039 Slow ~ Fast...
  • Page 6: Roduct Verview

    DIP-switches Power Link Out DMX Addressing IEC Plug for AC Input & Fuse Compartment Flush Mounting Bracket LED Front Panel ST-3000LED User Manual Hanging Yoke Audio Sensitivity Rotary knob DMX Output Red LED: Power Indicator Blue LED: Signal Indicator Introduction...
  • Page 7: Setup

    (2) Flush Mount Brackets for flush mounting to flat surfaces. You must supply your own clamp and make sure the clamp is capable of supporting the weight of this fixture. You can order C-clamps from any CHAUVET dealer or distributor.
  • Page 8: Fixture Linking

    Maximum recommended number of fixtures on a serial data link: 32 fixtures Data Cabling To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
  • Page 9: 3-Pin To 5-Pin Conversion Chart

    3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. CHAUVET Certified DMX Data Cables TANDALONE ASTER 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture.
  • Page 10: Operating Instructions

    “Master/Slave” configuration. Single-Fixture Mode The ST-3000LED can be set to operate independently of other fixtures or a DMX controller in either a sound-active or automatic mode. A serial data-link is not necessary for this mode of operation and it is recommended that no connection to other fixtures be made at all.
  • Page 11: Dmx Control Mode

    DMX C ONTROL The ST-3000LED can be operated from a DMX controller. This control mode environment gives the user the greatest flexibility when it comes to customizing or creating a show by enabling the control of each individual trait of the fixture and each fixture independently.
  • Page 12: Appendix

    Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
  • Page 13: Binary & Dmx Dip Switch Addressing

    = 16 Pin # 4 Total = 24 Resolving address using simple math. Address 233 ST-3000LED User Manual WITCH DDRESSING 9 10 9 10 233 – (128) = 105, Turn ON DIP # 8 DIP S 105 – (64) = 41, Turn ON DIP # 7 41 –...
  • Page 14: Binary Addressing Quick Reference Chart

    INARY DDRESSING DMX & Binary Address Quick Reference Chart DMX DIP SWITCH SET #9 0=OFF 1=ON X=OFF or ON DIP-switch Position DMX Address ST-3000LED User Manual UICK EFERENCE DIP switch Position Appendix HART 2009-12-10 14:04...
  • Page 15: Dmx Channel Values

    040  079 Program 1 080  119 Program 2 120  159 Program 3 160  199 Program 4 200  239 Program 5 240  255 Sound ST-3000LED User Manual ALUES Function Ch 2 Strobe 0  255...
  • Page 16: Technical Specifications

    Data pin configuration ... pin 1 shield, pin 2 (-), pin 3 (+) Protocols ... DMX-512 USITT DMX Channels ... 3 ORDERING INFORMATION LED Techno Strobe™ ... ST-3000LED ECHNICAL UPPORT Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com...