Step 4, Secure Wiring; Step 5, Size And Install Ductwork - GE Monogram ZXR8510 Installation Instructions Manual

Recirculating accessories for model zv850, island vent hood
Table of Contents

Advertisement

4 SECURE WIRING
• Route house wiring through the ceiling hole and
pull a length to reach the hood junction box,
approximately 6" below the support.
Front Side
Support
Frames
• Tape the wire to the front of the frame support to
prevent damage during installation and service.
Installation Instructions
Ceiling
Tape
House
Wiring
5 SIZE AND INSTALL DUCTWORK
• Measure from top duct connector (Dim. A) to
bottom of support frame.
– Add at least 1" for duct overlap at the top.
– Subtract 1-3/4" for hood insertion into the bottom
of the frame.
• Cut the 6" dia. duct to the required length.
Duct Connector
Side
View
Support
Frame
Duct Connection
To Hood
Note: The top and bottom of the duct are external
(female) connections. The bottom end should be
flared slightly, to facilitate installation of the hood.
• Install duct up through support frames onto the top
duct connector. Push duct up until it is 1-3/4" from
the bottom of support frame flange. See illustration.
8
Ceiling
Required
Dim. A
Duct
1-3/4"
Bottom Support
Frame Flange
Duct
Length