5. Alarm Characteristics
If interconnected to other Kidde alarms and the backup battery (if
equipped) is low or missing, or if the unit malfunctions, it will display
other readings (and alarm differently) to alert you of specific conditions.
Please familiarize yourself, and other family members, to the difference
between a CO reading and and indication signifying a problem with the
unit itself.
WARNING: If at any time you test the alarm and it does not perform as
described, have it replaced immediately.
NOTE: Reference to battery backup operation is only applicable to units
that are equipped with battery backup option.
Smoke Alarm Indicator (interconnected with CO Alarms)
When an interconnected Kidde smoke alarm detects smoke, the Kidde
CO alarm will sound a smoke/fire alarm pattern of 3 long beeps, fol-
lowed by 1 second of silence. This cycle repeats as long as smoke signal
persists to alert you of the condition. (For model KN-COP-IC with digi-
tal display: The word "Fire" will scroll across the digital display). If this
happens, leave the premises immediately by your escape plan and call
your local fire department.
WARNING: This unit is not a smoke alarm and will not detect smoke or
fire. It will only alarm for smoke/fire if it receives a signal from an inter-
connected Kidde smoke alarm.
NOTE: A smoke/fire alarm will override a CO alarm condition.
6. Model KN-COB-IC Operating Characteristics
Whenever the alarm is operating, the green Power LED is illuminated to
indicate the unit is monitoring for CO. If the alarm senses dangerous lev-
els of CO, the red Alarm LED will flash and the alarm will emit an audi-
ble alarm pattern.
Operating and Alarm Characteristics
Function
LED Display
Alarm Sound
Normal
Green LED
None
Operation
constantly on
Normal
Green LED flashes
None
Operation
every 7 seconds
Unit Status
Recommendation
Normal AC
None
operation (sensing
no CO) and with a
good battery
Normal DC
Verify AC power is
operation on 9V
restored as soon as
battery backup
possible to conserve
battery. Replace
battery.
6. Model KN-COB-IC Operating Characteristics
Function
LED Display
Alarm Sound
Carbon
Red LED flashes
4 quick beeps,
monoxide
with beeps.
5 seconds
alarm
Amber LED shows
silence,
initiating alarm
repeating
Smoke /
Red LED flashes
3 long beeps,
fire alarm
with beeps
1 second
silence,
repeating
Low
Red LED flashes
One quick
battery
every 15 seconds
beep every 15
seconds
Error /
Red LED flashes
One quick
service
every 30 seconds
beep every 30
alarm
seconds
Error
Red LED
Constant
constantly on
alarm
Normal
Red LED flashes
4 quick beeps,
Test/Reset
with beeps.
5 seconds
function
Green and amber
silence,
LED's on
repeated once
7. Model KN-COP-IC (with digital display)

Operating Characteristics

Whenever the alarm is operating, the green Power LED is illuminated
and the digital display will display "0" to indicate the unit is monitoring
for CO. If the alarm senses dangerous levels of CO, the red Alarm LED
will flash, the digital display will indicate the CO concentration in parts
per million (PPM), and the alarm will emit an audible alarm pattern.
This alarm will display a "0" if CO concentrations between 0 and 30
PPM have been detected within the last 15 seconds.
When the unit is first powered up, the digital display will show three
"eights" – indicating the alarm is in the start-up mode. The three
"eights" will remain for approximately 20 seconds. After 20 seconds,
the alarm should display "0" and begin monitoring the air for CO and
will continue to do so as long as it receives power.
Unit Status
Recommendation
Alarm condition.
Refer to "What to do
Dangerous
When the Alarm
concentrations of
Sounds" (inside front
CO detected
cover)
Receiving signal
Evacuate by your
from an intercon-
escape plan
nected smoke alarm
detecting smoke
AC powered and
Install or replace 9V
low or missing
battery.
battery
Unit is in error
Replace battery.
condition
If "Err" continues,
unit has malfunc-
tioned. Replace
Very low battery or
immediately. Unit will
not respond CO
unit malfunction
Normal operation
CO not detected.
when Test/Reset
Alarm for test
button is pressed
purposes only