Check Oil Level - MULTIQUIP Power MQP20P Operation And Parts Manual

20kw standby generator (perkins 404d-22 diesel engine)
Table of Contents

Advertisement

NOTICE
The air filter should be changed more frequently in
dusty operating conditions.
If the engine is operating in very dusty or dry grass
conditions, a clogged air cleaner will result. This can lead to
a loss of power, excessive carbon buildup in the combustion
chamber and high fuel consumption. Change air cleaner
more frequently if these conditions exist.
Fuel aDDiTiON
Add diesel fuel (the grade may vary according to season
and locations).
Removing Water from the Fuel Tank
After prolonged use, water and other impurities accumulate
in the bottom of the tank. Occasionally inspect the fuel tank
for water contamination and drain the contents if necessary.
During cold weather, the more empty volume inside the
tank, the easier it is for water to condense. This can be
reduced by keeping the tank full with diesel fuel.
Cleaning inside the Fuel Tank
If necessary, drain the fuel inside the fuel tank completely.
Using a spray washer (Figure 24) wash out any deposits
or debris that have accumulated inside the fuel tank.
Figure 24. Fuel Tank Cleaning
MQp20p STaNDBY geNeRaTOR • OpeRaTiON aND paRTS MaNual — Rev. #1 (11/28/11) — page 33
Fuel TaNk iNSpeCTiON
In addition to cleaning the fuel tank, the following
components should be inspected for wear:
„ Rubber Suspension — look for signs of wear or
deformity due to contact with oil. Replace the rubber
suspension if necessary.
„ Fuel Hoses — inspect nylon and rubber hoses for signs
of wear, deterioration, and hardening.
„ Fuel Tank lining — inspect the fuel tank lining for signs
of excessive amounts of oil and other foreign matter.
Replacing Fuel Filter
„ Replace the fuel filter cartridge with a new one every
500 hours.
„ Loosen the drain plug at the lower top of the fuel filter.
Drain the fuel in the fuel body together with the mixed
water. DO NOT spill the fuel during disassembly.
„ Vent any air.
aiR ReMOval
If air enters the fuel injection system of a diesel engine,
starting becomes impossible. After running out of fuel, or
after disassembling the fuel system, bleed the system.
Refer to the Perkins engine manual for details.

CHeCk Oil level

Check the crankcase oil level prior to each use, or when the
fuel tank is filled. Insufficient oil may cause severe damage
to the engine. The oil level must be between the two notches
on the dipstick as shown in Figure 7.
Replacing Oil Filter
1. Remove the old oil filter.
2. Apply a film of oil to the gasket on the new oil filter.
3. Install the new oil filter.
4. After the oil filter has been replaced, the engine oil will
drop slightly. Run the engine for a while and check for
leaks before adding more oil if needed. Clean excessive
oil from engine.
MaIntEnanCE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents