CAUTION: If you need to continuously reset the heater, the heater. When the room reached the desired temperature, unplug the unit and call Dimplex North America Limited at turn the thermostat knob counter clockwise until you hear a 1-888-346-7539.
② remove the log set from the unit. Set the 3 Position Switch to the Remote position (refer to Operation Section). 2. Locate and examine the bulbs to determine which bulb(s) required replacement. ③ Wait a minimum of five (5) seconds and then turn the 3.
Exploded Parts Diagram DS5603 Top Panel DS5804 Top Panel DS5598 Top Panel DS5804 Door Assembly DS5598 DS5598 Side Panel Door Assembly DS5804 Side Panel DS5603 Side Panel DS5603 Door Assembly...
Replacement Parts List DS5598, SS5800PB, SS5858N CATALOGUE NO . DS5598 SS5800PB SS5858N DS5598 6900330100 6900330100 6900330100 6900610100 6900610200 6900330700 6900330800 PART NO . 6900330400 MOD . LEVEL NONE MOD A & B MOD . C MOD B MOD NONE MOD . D MOD .
Main On/Off Switch Replacement cover and disconnect the wiring clips and connections noting their original locations. Tools Required: Philips head screwdriver NOTE: Use a flat head screwdriver to gently pry be- Flat head screwdriver tween the end of the connector and the switch to release the WARNING: If the fireplace was operating prior to servic- wires.
1. Remove the stove pipe kit (if equipped). 6. Locate the flicker motor and flicker rod assembly and remove the wiring clips and connections noting their 2. With front door closed, gently place stove door side down original locations. on a flat surface. 7.
Heater Assembly Replacement 12. Locate and remove the rear heater mounting screws. 13. Locate and disconnect the power cord wiring connec- Mod 0-B tions noting their original locations. Tools Required: Philips head screwdriver 14. With needle nose pliers grasp the power cord strain relief Flat head screwdriver grommet from inside the heater cover and push while twisting to remove.
Page 11
tween the end of the connector and the heater to release the wires. 19. Properly orient the new heater assembly and connect all of the wiring clips and connections. 20. Reassemble in the reverse order as above. Mod C and Higher Tools Required: Philips head screwdriver Flat head screwdriver WARNING: If the fireplace was operating prior to servic-...
Troubleshooting Guide PROBLEM CAUSE SOLUTION General Circuit breaker trips or fuse blows Short in unit wiring. Trace wiring in unit. when unit is turned on Improper circuit current rating Additional appliances may exceed the current rating of the circuit breaker or fuse. Plug unit into another outlet or install unit on a dedicated 15 amp circuit.
Page 13
PROBLEM CAUSE SOLUTION Heater Heater is not turning off Improper operation Refer to Operation Section Defective Heater On/Off Switch Replace Heater On/Off Switch Defective Thermostat Replace Thermostat Heater is not turning on, but flame Improper operation Refer to Operation Section effect is still functioning Loose wiring Trace wiring in unit...