NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNINg: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
OPERATION Remote Control To access the controls, go to the back of the stove (Figure The stove is supplied with an integrated On/Off remote control. NOTE: Ensure that the stove’s Three Position Switch is Figure 1 set to the remote Control setting (“II”...
SWITCH to OFF and waiting 5 minutes before switching the unit back on. Figure 4 Receiver CAUTION: If you need to continuously reset the heater, Outlet unplug the unit and call Dimplex North America Limited at 1-800-668-6663. Figure 3 OPEN OPEN Frequency...
MAINTENANCE Lower Bulbs Requirement: Quantity of three (3) 35 Watt Halogen Quartz lamps, 120 volt, G9 Base. WARNINg: Disconnect power before attempting any Do not exceed 35 Watts per bulb. maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. Lower Bulb Replacement Remove the stove pipe kit (if equipped).
! NOTE: To release Cams ensure arrow on Cam is facing the bottom of the stove and lower heater and light as- sembly out onto the floor. Remove the burnt out bulb(s) by pulling straight out arrow of socket. If bulbs are difficult to remove form socket www.dimplex.com...
Remove top panel. arrow Locate the upper light on/off switch mounted on the rear panel and disconnect the wiring clips and connec- tions noting their original locations. Remove top panel. Depress the retainer clips on the rear of the switch and Locate the heater on/off switch mounted on the rear push the switch out of the rear cover.
Open door by pulling the handles. Loosen the 2 retainers on the inner sides of the unit by turning counter clockwise. Remove 4 screws that secure the top on the rear of the unit. www.dimplex.com...
TROUBLESHOOTINg gUIDE PROBLEM CAUSE SOLUTION general Circuit breaker trips or fuse Short in unit wiring. Trace wiring in unit. blows when unit is turned on Improper circuit current rating Additional appliances may exceed the current rating of the circuit breaker or fuse. Plug unit into another outlet or install unit on a dedicated 15 amp circuit.
Page 12
Grinding or excessive noise with Moving flame rod hitting or rubbing Ensure rod is straight and mounted properly in the the heater off against internal components bracket, spinning freely away from other components. Replace if necessary. Defective flame motor Replace flame motor www.dimplex.com...