Auto Tile Matrix Monitors Read - NEC LCD Monitor Manual

Hide thumbs Also See for LCD Monitor:
Table of Contents

Advertisement

19.3 Auto Tile Matrix Monitors Read

This command is used in order to read the setting of H/V Monitors.
1) The controller requests the monitor to reply H/V Monitors setting.
Header
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'8'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'3' (43h, 41h, 30h, 33h): Auto Tile Matrix Command
'0'-'4' (30h. 34h): Monitors Read
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies H/V Monitors to the controller.
Header
SOH-'0'-'0'-Monitor ID-
'B'-'0'-'E'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', replying monitor's ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'E'(30h, 45h): Message length (14bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'3' (43h, 42h, 30h, 33h): Auto Tile Matrix reply
'0'-'4' (30h, 34h): Monitors Read
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
HM: H MONITORS
00h – 0Ah (30h, 30h – 30h, 41h)
VM: V MONITORS
00h – 0Ah (30h, 30h – 30h, 41h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Message
STX-'C'-'A'-'0'-'3'-'0'-'4'-ETX
Message
STX-'C'-'B'-'0'-'3'-'0'-'4'-
ST-HM-VM-ETX
(99/137)
Check code
Delimiter
BCC
CR
Check code
Delimiter
BCC
CR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multisync p403Multisync p463Multisync p553

Table of Contents