21.3 Setting Copy Start

This command is used in order to start Setting Copy.
1) The controller requests the monitor to write Setting Copy Start.
Header
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'8'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'9' (43h,41h,30h,39h): Setting Copy command
'0'-'2' (30h,32h): Start
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies to the controller.
Header
SOH-'0'-'0'-Monitor ID-
'B'-'0'-'A'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', replying monitor's ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'9' (43h, 42h, 30h, 39h): Setting Copy Reply
'0'-'2' (30h, 30h): Start
ST: Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 "Check code" for a BCC calculation.
Message
STX-'C'-'A'-'0'-'9'-0'-'2'-ETX
Message
STX-'C'-'B'-'0'-'9'-'0'-'2'-ST-ETX