All wiring must be performed by a licensed electrician in accordance with the National Electrical Code and all other applicable codes.
!
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Permit access for servicing motor as noted.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
Refer to the schematics below for the appropriate bath electrical installation. Dedicated15A circuits with GFCI (Ground
Fault Circuit Interrupter) protection are required.
At initial start-up with the power ON, push the GFCI test button. The reset button should pop out. Push this button in to
reset. If the GFCI fails to operate in this manner, there is a ground fault or malfunction, indicating the possibility of
electrical shock. Turn of the power and do not use until the source of the problem has been identifed and corrected.
ELECTRICAL
FEED
GFCI
WARNING: DO NOT PLUG PUMP DIRECTLY INTO THE GFCI OUTLET. PUMP MUST BE PLUGGED INTO THE OULET
PROVIDED ON THE CONTROL BOX AS PICTURED ABOVE.
whirlpool pump housing is plastic. Therefore, the conductor attached to the heater (if installed) must be
The silentjet
grounded directly to the home's electrical panel or approved local bonding point.
A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT IS REQUIRED IF THE OPTIONAL HEATER IS INSTALLED
(SEE INSTALLATION INSTRUCTIONS SUPPLIED WITH THE HEATER MODEL NUMBER - 494-1000).

ELECTRICAL INSTALLATION INSTRUCTIONS

120V, 60HZ
15A GFCI
AIR SWITCH ACTIVATED WHIRLPOOL PUMP