SEDONA L400PS Care & Use/Installation Manual page 28

Sedona
Hide thumbs Also See for L400PS:
Table of Contents

Advertisement

GaS connectionS... continued
lP Cylinder requirements
The LP cylinder must be constructed and marked in ac-
cordance with the specifications for LP gas cylinders of the
U.S. Department of Transportation (DOT) and designed for
use with a Type 1 system only.
your cylinder for a refill, exchange only for a Type 1 20lb
cylinder with an over-fill protection device.
Never use a cylinder with a damaged valve.
A dented or rusty LP cylinder may be hazardous and should
be avoided. If in doubt, have it checked by your LP supplier.
Always check for leaks after every LP cylinder change. (See
INDEX: "Leak Test" for further details.)
Always shut off the LP-gas supply at the cylinder when the
grill is not in use.
Cylinders must be stored outdoors in a well-ventilated area
out of the reach of children. If your grill is stored indoors,
the LP cylinder must be stored outside.
Place a dust cap on the cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap on
the cylinder valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result in leakage of
propane.
|
28
SEDONA CARE & USE/INSTALLATION
Cylinders of free
standing grills must be
secured using the pro-
vided cylinder reten-
tion system to avoid
accidental movement.
When exchanging
LP Connections
Make sure the LP cylinder valve is fully closed. It is possible
for the valve to be open without releasing gas but, as soon
as you start connecting the regulator, gas will leak from the
connection.
Insert the regulator inlet into the cylinder valve and turn the
black coupler clockwise until the coupler is hand tight. Do
not over-tighten this connection.
To disconnect the coupler, first make sure the main cylin-
der valve is turned off. Grasp the coupler and turn counter
clockwise. The inlet will then disengage.
Always leak-test the connection after refilling or exchanging
LP cylinders. (See INDEX: "Leak Test" for further details.)
GAS LINE PURGING
You should purge the gas line of air before attempting to
light the grill.
Make sure all grill controls are in the "OFF" position.
Slowly turn on the main gas supply.
Push in the left burner knob and confirm that the igniter is
sparking. It is furthest from the fuel source and will com-
pletely purge the lines. It will take several seconds for the
burner to light.
Hold the knob ON for about 20 seconds to allow the air in
the system to purge and the burner to light
Wait at least 5 minutes after shutting off the control before
attempting to light the burners.