Page 1
MAKE THE MOST OF YOUR SEDONA CARE & USE/INSTALLATION...
Page 2
3. California Proposition 65 lists “Silica, crystalline” which is used in one of the components of the IR burner, as an agent known to the state of California to cause cancer. PN #34170 SEDONA CARE & USE/INSTALLATION Rev. D 02/15...
Page 3
13. THIS MANUAL MUST REMAIN WITH THE PRODUCT OWNER FOR FUTURE REFERENCE. This product complies with ANSI standard Z21.58/CSA 1.6 latest edition and has been tested and approved by Intertek. To obtain replacement parts or service contact: Lynx Professional Grills 7300 Flores Street Downey, CA 90242 888-289-5969 SEDONA CARE & USE/INSTALLATION...
Final Checks Leak Testing Wiring Schematics L400/L500 Non-Rotisserie Grill L400/L500 Rotisserie Grill L600/L700 Non-Rotisserie Grill L600/L700 Rotisserie Grill Sedona Grill Exploded Parts View Sedona Grill Parts List Model Specific BTU Outputs Maximum Runs for all Appliances Index SEDONA CARE & USE/INSTALLATION...
If your grill has been unused for a long time, inspect and clean the burners, venturis, valves and orifices. (See INDEX: “Cleaning the Burner” for 10. Never use charcoal or any other solid fuel in the grill. further details.) SEDONA CARE & USE/INSTALLATION...
These high-performance burners require a constant, Wind hitting the back of steady supply of fresh air to mix with the fuel. Your Sedona the grill can disrupt proper grill pulls air in through the front and vents hot gases out exhaust.
• A qualified plumber has performed a leak test on all the fittings that supply fuel to your grill. IF YOUR GRILL DOES NOT LIGHT IN 4 TO 5 SECONDS you may need to purge the line. (See INDEX: “Purging the Gas Line” for further details.) SEDONA CARE & USE/INSTALLATION...
If the burners do not light with in 5 seconds, turn the knob burner. to OFF and wait 5 minutes for gas to dissipate, and repeat the step above. SEDONA CARE & USE/INSTALLATION...
Page 9
“LITE” position. Hold the knob in for at least 30 seconds. If the burner does not stay lit, turn the knob OFF and wait 5 minutes for gas to dissipate before attempting to light it again. SEDONA CARE & USE/INSTALLATION...
Indirect heat cooking occurs when the food is not close to burner, using the hood thermometer to monitor the tem- the heat source. Heat reaches the food via air movement perature. within the cooking area. This form of heat is known as “convection” heat. SEDONA CARE & USE/INSTALLATION...
ProSear™ burner and should not use water to control flare-ups. Take special care to minimize dropping water on the ProSear™ burner while cleaning the cook- ing grids. SEDONA CARE & USE/INSTALLATION...
But BE SURE YOU REMOVE IT before using The notched portion of the skewer must rest on the sup- any of the other burners. port for proper operation. (see photo at right) SEDONA CARE & USE/INSTALLATION...
Page 13
If the burner will not remain lit refer to the troubleshooting guide for assistance. MUST REST ON SUPPORTS Notched portion of the skewer must rest on the support SEDONA CARE & USE/INSTALLATION...
TO ACCUMULATE IN THE DRIP TRAY AS THIS MAY product. CREATE A FIRE HAZARD. Here are a few tips to avoid this: NEVER USE GRILL WITHOUT DRIP TRAY PROPERLY INSTALLED. SEDONA CARE & USE/INSTALLATION...
Page 15
Remove stubborn scale with When re-installing the ProSear™ burner, be sure to cor- a metal scraper. rectly position the burner. Replace the hex head screw to secure the burner. Clear any clogged ports with a straightened paper clip. Never SEDONA CARE & USE/INSTALLATION...
RELEASE Hold the bulb using a paper towel or other cloth and gen- further details.) LIGHT tly press it straight into the socket. The glass cover should COVER be gently snapped back into place. Spark Igniter SEDONA CARE & USE/INSTALLATION...
Page 17
• Clean or adjust air shutter (See INDEX: “Air Shutter • Check the regulator Adjustment.” Make sure that the regulator & hose assembly is the one designed for and supplied with your grill and that it is SEDONA CARE & USE/INSTALLATION...
For warranty service, contact the Lynx Customer Care Tel: (562) 299-6900 Department for an authorized service agent near you at: Fax: (562) 299-6978 • (888) 289-5969 www.lynxgrills.com • www.lynxgrills.com Contact Lynx Customer Care for replacement parts. Parts are shipped F.O.B. Commerce, CA. SEDONA CARE & USE/INSTALLATION...
4) Warranty shall not apply and Lynx is not responsible 8) The cost of a service call to diagnose trouble. for damage resulting from misuse, abuse, alteration of or tampering with the appliance, accident, hostile environ- SEDONA CARE & USE/INSTALLATION...
Leak Testing Wiring Schematics L400/L500 Non-Rotisserie Grill L400/L500 Rotisserie Grill L600/L700 Non-Rotisserie Grill L600/L700 Rotisserie Grill Sedona Grill Exploded Parts View Sedona Grill Parts List Model Specific BTU Outputs Maximum Runs for All Appliances on Supply Line SEDONA CARE & USE/INSTALLATION...
Page 21
2. All permanently-installed natural gas or propane installations require a “T” handle type manual gas valve be installed in the gas supply line to this appliance. 3. This does not apply to portable propane installations using a 20 pound cylinder. SEDONA CARE & USE/INSTALLATION...
If the grill is to be placed in a combustible enclosure an approved insulating jacket is necessary. Order model number LIJ400, LIJ500, LIJ600 or LIJ700 depending on your grill size. SEDONA CARE & USE/INSTALLATION...
The rating plate is located in one or more of the following warranty. places: • Attached to the underside of the drip tray • On the heat shield behind the front panel The grill is factory set to use either propane (LP) or natural SEDONA CARE & USE/INSTALLATION...
(See INDEX: “Gas must be sized to accommodate the total BTU requirements of Connections” for typical permanent hook up.) NATURAL GAS HOOK-UP BOTTLED LP HOOK-UP 3 Typical Natural Gas 2 Typical LP Bottle Installations Installations SEDONA CARE & USE/INSTALLATION...
Always shut off the LP-gas supply at the cylinder when the grill is not in use. Cylinders must be stored outdoors in a well-ventilated area out of the reach of children. If your grill is stored indoors, the LP cylinder must be stored outside. SEDONA CARE & USE/INSTALLATION...
GAS LINE PURGING You should purge the gas line of air before attempting to light the grill. LP GAS HOOK UP NATURAL GAS/LP BULK-TANK HOOK UP L.P. GAS HOOK-UP NATURAL GAS HOOK-UP LP BULK-TANK HOOK-UP SEDONA CARE & USE/INSTALLATION...
GFI may have tripped, requiring a reset. See the Troubleshooting section for 4. Insert and/or replace a new 1. Locate the battery compartment 3. The battery compartment will more details. 9V battery disengage and protrude SEDONA CARE & USE/INSTALLATION...
The main burners and side burners on your grill feature an If your flames do not match those indicated in the photo, adjustable low setting. ensure that the air shutter and burner ports are free and SEDONA CARE & USE/INSTALLATION...
Page 31
Finally, for safety and for proper use & care, you must leave this manual with the owner. Make sure you advise them to keep it for future reference. For technical assistance call: Lynx Customer Care 888-289-5969 SEDONA CARE & USE/INSTALLATION...
APPLIANCES ON SUPPLY LINE WITH NATURAL GAS IT SHOULD BE NO LONGER THAN 12 FEET. Run Length Max BTU for all 3/4” Pipe (in feet) Appliances on line 360,000 245,000 198,000 169,000 150,000 135.000 123,000 115,000 SEDONA CARE & USE/INSTALLATION...
Maximum Runs for all Connection to AC ....29 appliances on supply line ..38 Warranty ........19 Windy Conditions, Grilling in ..6 PRO-SEAR is a trademark of the W.C. Bradley Company. Used with permission. SEDONA CARE & USE/INSTALLATION...
Lynx Professional Grills 7300 Flores Street Downey, CA 90242 Lynx Customer Care: 888.289.5969 Fax: 562-299-6978 www.lynxgrills.com PN #34170, Rev. D 02/15 SEDONA CARE & USE/INSTALLATION...