If you run into a problem, refer to the troubleshooting table below.
SymPtom
The refrigerator has stopped cooling.
Refrigerator or freezer is not cold
enough
The refrigerator does not work on
120V aC
The refrigerator does not work in gas
operation mode
Odors from fumes
If the problem persists and the refrigerator is still not working properly, contact your nearest service Center. state the problem,
model, product- and serial-number. These details are stated on the data label inside the refrigerator compartment.
WaRningS
For information about warnings, refer to the following table. The messages are displayed flashing (alternating between
temperature and the message).
WaRningS
infoRmation
LP
Gas ignition failed. Gas bottle empty, the manual valve(s) are closed or burner jet clogged.

tRoUblEShooting

chEck/REmEdial action
Immediately turn the refrigerator off and see a Dometic dealer.
Check the thermostat and adjust if necessary.
Is there a power failure?
Is the refrigerator level? (Because of its operation it is important to keep an
absorption refrigerator level.)
has the overheating protection been triggered or not?
Door closing properly? Check the door gasket.
heavy frost build-up on evaporator fins? To prevent frost buildup do not leave the
unit's door open longer than necessary.
Overpacked refrigerator? The unit will have to work harder if the refrigerator is
stuffed and results in higher cabinet temperatures. arrange the food in the unit to al-
low for free air circulation.
Is the plug firmly connected to the receptacle? Is the socket switched on? Check the
receptacle by plugging in another appliance.
are the fuses intact for the aC supply and control system?
Gas bottle empty?
Change the gas bottle
air in the gas pipe?
see
REFRIGERaTOR OVERVIEw > PuRGING aIR FROM ThE LINEs
Is the burner dirty, damaged or not properly located under the flue tube?
Is the burner jet clogged?
Is the flue baffle inserted properly in the flue tube?
Is the LP gas pressure low at burner?
set the main regulator to regulate the pressure so it does not drop below 11 inches
water column at pressure tap.
Dislocated burner
Damaged burner
Dirty flue tube
- 1 -