Daikin ENVi Installation Manual page 24

Hide thumbs Also See for ENVi:
Table of Contents

Advertisement

20
reached). Options are Auto (default) and 1 to
10 °F (0.6 to 5.6 °C).
Only visible if Indoor Unit supports heat and an
auxiliary heat source is also configured.
Heat Pump to Aux Runtime
amount of time the heat pump will run
before engaging Aux Heat. Options are Auto
(default), Disabled, and 10 to 180 minutes.
Only visible if Indoor Unit supports heat and an
auxiliary heat source is also configured.
Aux Heat Settings
The Aux Heat Settings configure an auxiliary heat
source.
If you want to test the auxiliary heater during
installation, set Aux Heat Installed to Yes and set
Allow HP with Aux Heat to No. Then, adjust the heat
set point to enable the auxiliary heater.
Aux Heat Installed
configures the thermostat to control an
auxiliary heat source.
Aux Heat Requires Fan
configures the thermostat to control the fan
when auxiliary heat is used.
Allow HP with Aux Heat
it will turn on auxiliary heat in addition to
the heat pump. For information about how
auxiliary heat will be engaged with the heat
pump, see the settings
Temp Delta
Aux Min On Time
equipment run time for auxiliary heat: 1 to 20
min (default is 5 min).
Max Outdoor Temp
maximum outdoor temperature threshold.
When set to Yes,
When set to Yes,
When set to
Heat Pump to Aux
and
Heat Pump to Aux
Sets the minimum
Configures the
The maximum
Yes,
Runtime.