Recovery

The surest way to reset the power distribution system after a
shutdown triggered by the environmental monitor is to cycle the
primary power (remove and reconnect the –48Vdc or 115/230Vac
input power).
In systems with a redundant power supply, setting the key switch
on the Modular Chassis to
or undervoltage failure does restart the power supply, but requires
that the operating system first be shut down.

Operating Procedures

System operation with a Modular Chassis and XR900 is entirely
dependent on your choice of modules and software. Only the basic
power on/power off procedure and remote interface are discussed
here. For additional operational information, refer to the user's
manual(s) for the modules used in the chassis.

Recommended Power-On Procedure

The XR900 has no power switch. The power supply cycles on and
off under the control of the host computer (i.e., through application
of the SCSI
and if that fuse blows, it is advisable to replace the power supply.
1. Verify that all chassis, modules, and associated data/control
cabling are properly configured and installed. If the system is
rack-mounted, also check that all required external cabling
(to non-rack-mounted equipment) is correctly installed.
2. On the Modular Chassis, verify that the power switch is set to
STANDBY
STANDBY
signal). The only fuse is in the power supply
TERMPWR
(off).
Operating Procedures
and back to
after a thermal
RUN
3
3-5