Fuse Replacement; Specifications - Vector VEC061 Owner's Manual & Warranty

350 watt power inverter
Table of Contents

Advertisement

9.

FUSE REPLACEMENT

If external fuses blow, (or breakers trip), then there is a short or overload
in the DC wiring. Find and fix the problem before replacing the fuses (or
resetting the breaker). After fuse replacement, reconnect the inverter.
This power inverter is equipped with multiple internal fuses. Normally,
these fuses will not blow unless there is a serious problem inside the unit.
Internal fuses are replaceable, however, only electronically knowledgeable
people should attempt fuse replacement. If the unit is damaged during fuse
replacement, the warranty may be voided. Vector recommends contacting
Vector Technical Support for guidance. Based on experience, it is best to
return the unit to Vector for repair. Vector Technical Support can be
reached by calling 954-584-4446, extension 19 or toll-free 866 584-
5504.
You
website@www.vectormfg.com.
10.

SPECIFICATIONS

Output Connection ..........Dual North American Standard Receptacles
Output Voltage......................................Approx 110 VAC RMS 60 Hz
Output Current ..................................................................3.2 Amps
Continuous Output Watts ............................................................350
Peak Output Watts ......................................................................700
Output Waveform ..................................Modified Sine Wave (filtered)
Input Voltage Range ..............................................10.5 to 14.7 VDC
Low Voltage Alarm ............................................................10.5 VDC
Low Voltage Shutdown........................................................10.0 VDC
No Load Input Current ........................................................0.4 Amps
Input Fuses ............................................................................Internal
Input Cables:..............................One Cig Light Plug (up to 150 Watts)
Battery Clip Cable (up to 350 watts)
Additional Protection ..........................Overload, Over volt, Over temp
Auto-Recover from shutdown ................................................Self reset
Weight..................................................................1.55 Lbs (0.70 kg)
Length ..................................................................4.5 in. (11.43 cm)
Width ..................................................................1.75 in. (4.45 cm)
Height ..................................................................4.5 in. (11.43 cm)