Server Blade, Expansion Blade, and Fan Population Guidelines
Fan & power supply bay numbering
Rack power supply bay numbering
Power supplies and fans must be placed in the following bays
Number of Fans
4
6
Number of Power Supplies (for PS Redundant or non-redundant
mode)
2
3
4
5
6
Number of Power Supplies (for AC Redundant mode)
2
4
6
NOTE: With four fans, the enclosure will support only 4 half-height server blades in the bottom half of the enclosure device bays. With
six fans, all 8 server bays may be filled.
NOTE: For correct operation, fans and server blades must be installed in the correct bays. The Onboard Administrator will ensure that
fans and blades are correctly placed before allowing the system to power on.
DA - 12790 North America — Version 55 — December 10, 2013
HP BladeSystem c3000 Enclosure
Fan bay numbering
Fan Bays Used
2,4,5, 6
All bays filled
Power Supply Bays Used
1 & 2
1, 2, & 3
1, 2, 3, & 4
1 through 5
All bays
Place Power Supplies in Bays:
1 & 4
1, 2, 4, & 5
All bays filled