BEDIENUNGSANWEISUNG mit Montageanweisungen Instructions for use and installation instructions Instructions d’ utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem KD 966.1/KDEM 966.1...
Preparing the chimney Installation of the exhaust channels Electric connection Installing the chimney Screwing the control element tight Inserting the metal fat filters Guideline for extraction paths ..20 KD 966.1 / KDEM 966.1...
The room Moisture — If the cooker hood is only used in recirculation mode - with activated air is charcoal filters - there are no restrictions on operation Heat — cleaned of Odours KD 966.1 / KDEM 966.1...
6 months. There is no sepa- pressing this button again. rate display for renewing the activated charcoal filters. You can obtain origi- nal filters from your dealer or direct from KÜPPPERSBUSCH. KD 966.1 / KDEM 966.1...
If the control lights still flash when the hood is used for the first time af- – ter cleaning, press one of the lower three buttons. The counter for the operating hours is then reset to 0 and the control lights go off. KD 966.1 / KDEM 966.1...
Please make a note of the following data on the rating label before or while installing the cooker hood in case you have to consult our Customer Service: Serial number: Model designation: KD 966.1 / KDEM 966.1...
Drill the holes and insert dowels. – Guide the power cable and, if provided, the control line of the external mo- tor through the opening in the rear panel and screw on the panel. Recirculation KD 966.1 / KDEM 966.1...
For extraction mode the ventilation slits in the upper chimney part must be wall or ceiling. turned downwards. Connect the hood body to the extraction channel. – Electric connection Plug the mains plug into the socket. – The household fuse must still be switched off! KD 966.1 / KDEM 966.1...
Reach through the right-hand side – of the opening at the bottom of the hood body and tighten the control element with the knurled screws. Make sure that all the control buttons protrude slightly forwards out of the chimney. KD 966.1 / KDEM 966.1...
The exhaust air must only be introduced into an existing exhaust shaft if this is insulated against damp and is not already used for fuel purposes. Have the chimney sweep responsible approve the use of the shaft. KD 966.1 / KDEM 966.1...