Tripp Lite SRXCOOL33K Features & Specifications

Tripp Lite SRXCOOL33K Features & Specifications

33,000 btu energy-saving, row-based air conditioning unit with hardwire input
Hide thumbs Also See for SRXCOOL33K:

Advertisement

Model #: SRXCOOL33K
33,000 BTU Energy-Saving, Row-Based Air Conditioning Unit with Hardwire Input
Description
The harder your data center, network closet or server room works, the more it heats up, leading to inefficient operation, weakened performance and
raised cooling costs. In fact, cooling can consume more than half of the power used by a high-density installation—start saving power and money
with Tripp Lite's SRXCOOL33K today! The SRXCOOL33K provides 33,000 BTU of efficient, reliable cooling in a 42U rack form factor. It features
cutting-edge components that limit inrush current and enable precision cooling adjustments to minimize power consumption, maximize cooling and
improve your application efficiency.
By delivering cold air high in the cold aisle, the SRXCOOL33K promotes temperature uniformity from 1U to 42U, allowing your equipment to perform
at its peak. Controlling the unit is simple with the intuitive LCD display, or control it from anywhere in the world with the included Modbus card or an
optional network interface (Tripp Lite SNMPWEBCARD, sold separately). With hardwire input (user supplied IEC 309 32-amp set, optional) and
exhaust connection directly into the drop ceiling, you can install the unit with no electrician or contractor necessary, saving on up-front installation
costs. Maintenance is no-hassle due to the self-contained design, which requires no water collection tank or extra plumbing, while RoHS compliance
and eco-friendly R410a refrigerant means you'll never have to worry about meeting environmental standards.
Applications
Supplemental cooling of data center equipment in confined areas where the facility HVAC is inadequate or doesn't reach.
Package Includes
SRXCOOL33K Air Conditioning Unit
Flexible Air Ducts
Unpacking Guide, Installation Manual and Owner's Manual
Unloading Ramps
Hot Exhaust Removal Tube
Owner's Manual
Features
33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption
Variable-speed, DC-inverter-driven compressor and microprocessor-controlled electronic expansion valve (EEV) enable precision cooling
adjustments--no more wasteful, noisy cycling between off and full blast
Soft-start feature limits inrush current to prevent introduction of line noise, voltage disruptions and potential circuit overloads
Self-contained, zero-maintenance unit re-humidifies condensate and expels it through the exhaust air stream--no floor drain, water
collection tank, external condenser, refrigerant piping, duct work or plumbing required
Convenient LCD control panel and network interface provide local and remote monitoring and control of temperature, humidity, fan speed,
Highlights
33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption
Variable-speed, DC-inverter-driven compressor and microprocessor-controlled
electronic expansion valve (EEV) enable precision cooling adjustments--no
more wasteful, noisy cycling between off and full blast
Soft-start feature limits inrush current to prevent introduction of line noise,
voltage disruptions and potential circuit overloads
Self-contained, zero-maintenance unit re-humidifies condensate and expels it
through the exhaust air stream--no floor drain, water collection tank, external
condenser, refrigerant piping, duct work or plumbing required
Hardwire Input (User-supplied IEC 309 32-amp set, optional) - no electrician
needed
200-240V AC Input, 50/60 Hz frequency compatibility
1 year limited warranty
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail:
saleshelp@tripplite.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the SRXCOOL33K and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tripp Lite SRXCOOL33K

  • Page 1 By delivering cold air high in the cold aisle, the SRXCOOL33K promotes temperature uniformity from 1U to 42U, allowing your equipment to perform at its peak. Controlling the unit is simple with the intuitive LCD display, or control it from anywhere in the world with the included Modbus card or an optional network interface (Tripp Lite SNMPWEBCARD, sold separately).
  • Page 2: Specifications

    Convenient LCD control panel and network interface provide local and remote monitoring and control of temperature, humidity, fan speed, alarms and logging via front-panel buttons, SNMP, Web, telnet/SSH or Modbus Row-based airflow path maximizes hot-aisle/cold-aisle efficiency and cooling predictability by supplying cold intake air high in the cold aisle and removing hot equipment exhaust air high in the hot aisle Hardwire (User-supplied IEC 309 32-amp set, optional) - no electrician needed RoHS compliance and R410A refrigerant meets environmental standards worldwide...
  • Page 3 Copyright © 2013 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.