Download Print this page

HP 12500 Series Specification page 30

12500 series

Advertisement

QuickSpecs
Technical Specifications
HP 12508 DC Switch Chassis (JC652A)
Ports
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics Maximum heat
Safety
Emissions
Immunity
HP sales office
8 open module slots
2 MPU (for management modules) slots
9 switch fabric slots
Supports a maximum of 256 10GbE ports or 384 Gigabit Ethernet ports, or a combination
Dimensions
Weight
Full configuration weight 374.78 lb. (170 kg)
Gigabit Module
10G Module
Management Module
Fabric
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet
Throughput
Routing/Switching
capacity
Operating temperature
Operating relative
humidity
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
dissipation
DC voltage
Maximum power rating
Notes
CE Labeled; cUL Certified; UL Listed; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of
Laser Products-Part 2; IEC 60825; IEC 60950-1:2001 (with CB Report); CAN/CSA-C22.2 No. 60950-1-03;
Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; UL 60950-1:2003; EN 60950-
1:2001; ROHS Compliance
VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR22 Class A; EMC
Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Generic
DA - 13785 North America — Version 20 — January 16, 2014
17.4(d) x 29.13(w) x 38.39(h) in. (44.2 x 73.99 x 97.51 cm) (22U height)
209.44 lb (95 kg)
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB RAM (Ingress,
shared by 24 1-GbE ports)
PowerPC @ 667 MHz, 1 GB RAM; packet buffer size: 512 MB (Ingress/shared by
2 10GbE ports)
Primary CPU: PowerPC @ 1000 MHz, 128 MB flash MB, 256 MB compact
flash, 4 GB RAM
PowerPC @ 400 MHz, 128 MB RAM MB
1920 million pps
6120 Gbps
32°F to 104°F (0°C to 40°C)
5% to 95%, non-condensing
-40°F to 158°F (-40°C to 70°C)
5% to 95%, non-condensing
14587 BTU/hr (15389.29 kJ/hr)
-48 to -60, rated/-40 to -72, maximum, VDC
4750 W
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with
fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all
modules populated.
ETSI EN 300 386 V1.3.3