Operation; Description Of The Six Different States - Bosch MIYN46 User Manual

Wall transmitter
Table of Contents

Advertisement

20
en | Operation
6

Operation

6.1

Description of the six different states

During operation, the MIYN46 Wall Transmitter can be set to one of six following states:
State
Stand-by
Alarm without staff presence
Alarm with staff presence
Assistance without staff presence
Assistance with staff presence
Staff Presence without alarm
Each state is indicated by the signal lamp and by a special position of the output relays.
It is possible to configure the MIYN46 Wall Transmitter in order that:
The transition to a specific condition depends on the device configuration, of its actual condi-
tion and of the action completed; as shown on the charts in the following chapters.
NOTICE!
i
When the MIYN46 Wall Transmitter is powered by an external power supply, the signal lamps
follow the state of the corresponding relay outputs.
970.035b | F.01U.278.521 | v2.0 | 2012.12
the Call for Assistance can be triggered only if the Care Personnel is present.
the device does not manage the Staff Presence. This mode makes sense only if the
output relays are not provided or not used.
User Manual US
Description
No call is being processed.
The resident has triggered a Call for Help but the Care
Personnel has not yet responded.
The Care Personnel has responded after a Call for Help.
A Call for Assistance has been triggered without the
presence of the Care Personnel.
A Call for Assistance has been triggered in the presence
of the Care Personnel.
The Care Personnel has responded without a previous
call from the resident.
MIYN46 Wall Transmitter
Bosch Security Systems

Advertisement

Table of Contents