Range
400.0uA
4000uA
40.00mA
400.0mA
10A
Overload Protection: 0.5A / 1000V and 10A / 1000V Fuse.
Maximum Input:
AC Current (Auto-ranging)
Range
400.0uA
0.1uA
4000uA
1uA
40.00mA
10uA
400.0mA
100uA
10A
Overload Protection: 0.5A / 1000V and 10A / 1000V Fuse.
AC Response: 50 Hz to 60 Hz
Maximum Input:
Resolution
0.1uA
1uA
10uA
100uA
10mA
400uA dc on uA range
400mA dc on mA range
10A dc on 10A range.
Resolution
10mA
400uA ac rms on uA
400mA ac rms on mA
10A ac rms on 10A range.
Accuracy
+1.2% of rdg + 3 digits
+2.5% of rdg + 3 digits
Accuracy
+1.5% of rdg + 5 digits
+3.0% of rdg + 5 digits