Instruction Manual
3in1 Pocket Autoranging DMM
PDMT05
Hz%
DT-118B
OFF V
A
Features
3-3/4 digit 4000 count) LCD display
Built-in non-contact AC voltage detector
plus flashlight
Double Molded housing
CATIII 1000V
200mA/500V Resettable Fused current inputs and
Overload protection on all ranges
Autoranging with auto power off
www.pyleaudio.com
Safety
International Safety Symbols
This symbol, adjacent to another symbol or
terminal, indicates the user must refer to the manual
for further information.
This symbol, adjacent to a terminal, indicates that,
under normal use, hazardous voltages may be
present.
Double insulation
Safety Precautions
1.
Improper use of this meter can cause damage, shock, injury or
death. Read and understand this users manual before
operating the meter.
2.
Make sure any covers or battery doors are properly closed and
secured.
3.
Always disconnect the test leads from any voltage source
before replacing the battery or fuses.
4.
Do not exceed the maximum rated input limits.
Input Limits
Function
Maximum Input
V DC or V AC
600V DC/AC
µA AC/DC
200mA/500V fast acting
Resettable Fuse
Resistance, Diode &
600V DC/AC
Continuity Test
5.
Use great care when making measurements if the voltages are
greater than 25VAC rms or 35VDC. These voltages are
considered a shock hazard.
Always discharge capacitors and remove power from the
6.
device under test before performing Diode, Resistance or
Continuity tests.
Remove the battery from the meter if the meter is to be
7.
stored for long periods.
Meter Description
1.
Non-contact AC voltage detector probe tip
2.
Non-contact AC voltage indicator light
3.
3 3/4 Digit (4000 count)
4.
MODE button
5.
Function switch
6.
Flashlight
1
2
7.
Flashlight button
3
8.
Hz/%Duty button
4
9.
Battery Cover
A
5
10.
Test leads
9
Specifications
Electrical Specifications
Function
DC Voltage
AC Voltage
50-60Hz
DC Current
AC Current
50-60Hz
Resistance
Capacitance
Frequency
Duty Cycle
Max input voltage
Diode Test
Continuity Check
Display
Over range indication
Polarity
Low Battery Indication "BAT" symbol indicates low battery
Input Impedance
AC Response
ACV Bandwidth
Auto Power Off
6
Fuse
Batteries
7
10
8
Operating Temperature 32
Storage Temperature
OFF
V
Weight
Size
Standard
Range
Accuracy
400mV,
(0.5% rdg + 3d)
4.000V,40.00V, 400.0V,
(1.2% rdg + 3d)
600V
(1.0% rdg + 8d)
4.000V, 40.00V
400.0V, 600V
(2.3% rdg + 10d)
(2.0% rdg + 8d)
400.0µA, 4000µA
40.00mA, 200.0mA
(2.5% rdg + 10d)
400.0µA, 4000µA
40.00mA, 200.0mA
(0.8% rdg + 5d)
400.0
(1.2% rdg + 5d)
4.000k, 40.00k,
400.0k
(5.0% rdg + 5d)
4.000M
(10.0% rdg + 5d)
40.00M
(5.0% rdg + 0.6nF)
4.000nF
40.00nF
(5.0% rdg + 30d)
400.0nF
(3.0% rdg + 15d)
(5.0% rdg + 25d)
4.000µF, 40.00µF,
200.0µF
9.999Hz, 99.999Hz,
(2.0% rdg + 5d)
999.9Hz, 9.999kHz,
0.5-99%
(2.0% rdg + 5d)
600V AC/DC
Test current 1mA max., open circuit voltage
of 1.5V typical
Audible signal if the resistance is <100
4000 count 3 -3/4 digit LCD
LCD displays "OL"
Minus (-) sign for negative polarity.
condition.
>7.5MΩ (VDC & VAC)
Average responding
50Hz to 60Hz
15 minutes (approximately)
fast acting
mA, µA ranges; 0.4A/600V
Resettable Fuse
Two 1.5V AAA
o
o
o
o
F to 104
F (0
C to 40
C)
o
o
o
o
14
F to 122
F (-10
C to 50
C)
145g
104x55x32.5mm
IEC61010-1 CAT III 1000V Pollution
degree II, CE Approved