SECTION 4 − SPECIFICATIONS AND INSTALLATION
4-1. Serial Number And Rating Label Location
The serial number and rating information is located on the bottom of the machine. Use the rating labels to determine input power requirements and/or
rated output. CE model rating labels will also display the following symbols: CE, CCC, WEEE, and IEC 60974-1. For future reference, write serial
number in space provided on back cover of this manual.
4-2. Specifications
Input Power
Rated Welding
Single-Phase
Output
AC
70A @ 22.8 Volts DC,
100% Duty Cycle
115 Volts Stick
100A @ 24.0 Volts DC,
35% Duty Cycle
100A @ 14.0 Volts DC,
100% Duty Cycle
115 Volts TIG
150A @ 16.0 Volts DC,
30% Duty Cycle
100A @ 24 Volts DC,
100% Duty Cycle
230 Volts Stick
150A @ 26.0 Volts DC,
30% Duty Cycle
100A @ 14.0 Volts DC,
100% Duty Cycle
230 Volts TIG
150A @ 16.0 Volts DC,
30% Duty Cycle
*Sense Voltage For Stick And TIG Lift Arct
4-3. Duty Cycle And Overheating
250
200
150
100
Welding
Max
Amperage
OCV
Range
DC
69V
20 − 100A
*12-16
69V
5 − 150A
*12-16
69V
20 − 150A
*12-16
69V
5 − 150A
*12-16
TIG (115 &230V)
Stick (230V)
Stick (115V)
50
0
10
% Duty Cycle
Amperes In-
KVA @
put At Rated
Load Output,
Duty
KW
Cycle
50/60Hz,
Single-Phase
17.4
2.0
1.9
26.4
3.0
3.0
18.4
2.1
2.1
28.0
3.4
3.1
13.1
3.0
2.8
21.6
4.9
4.7
8.3
2.0
1.9
14.2
3.2
3.1
100
Dimensions
Weight
H: 9 in (229 mm)
13.7 lb
(6.2 kg)
W: 5.5 in (140 mm)
L: 13.25 in (337 mm)
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, the
Overtemperature Light comes On,
and the cooling fan runs. Wait fif-
teen minutes for unit to cool. Re-
duce amperage or duty cycle be-
fore starting to weld again.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
208 608-C
OM-220 340 Page 13