Circuit Breakers; Troubleshooting - Unitor UWI 400 Owner's Manual

Arc welding power source 380/440 volt model
Hide thumbs Also See for UNITOR UWI 400:
Table of Contents

Advertisement

6-4. Circuit Breakers

6-5. Troubleshooting

Trouble
No weld output; unit completely inop-
erative.
erative
No weld output; meter display On.
Erratic or improper weld output.
No 110 volts ac output at Remote 14
receptacle.
No 24 volts ac output at Remote 14 re-
ceptacle.
1
Place line disconnect switch in On position (see Section 4-9).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-9).
Check for proper input power connections (see Section 4-9).
If using remote control, be sure Mode Selector switch is in a position that provides output control at
Remote 14 receptacle.
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fan On (see Section 4-2).
Use proper size and type of weld cable (see Section 4-6).
Clean and tighten all weld connections.
Reset circuit breaker CB1 (see Section 6-4).
Reset circuit breaker CB2 (see Section 6-4).
1
Circuit Breaker CB1
2
Circuit Breaker CB2
CB1 protects 110 volt ac portion of
Remote 14 receptacle from over-
load.
CB2 protects 24 volt ac portion of
Remote
overload.
Press button to reset breaker.
2
Remedy
14
receptacle
from
Ref. ST-801 245-A
OM-202 137 Page 27