Checking Or Replacing Filter Element (Part No. 227 877) - Miller Electric Spectrum 875 Auto-Line Owner's Manual

Air plasma cutter
Hide thumbs Also See for Spectrum 875 Auto-Line:
Table of Contents

Advertisement

7-5. Checking Or Replacing Filter Element (Part No. 227 877)

1
2
Tools Needed:
OM-242 880 Page 42
.
A complete Parts List is available at www.MillerWelds.com
3
4
5
5/16 in.
!
Turn
off
power,
and
disconnect input power plug
from receptacle or turn off
and lockout/tagout line dis-
connect
device
before
working on unit.
!
Significant DC voltage can
remain on capacitors after
unit is Off. Check to see that
front panel lights (LEDs)
have stopped flashing and
are off before removing
wrapper.
Remove wrapper from unit (see
Section 7-4).
1
Rear Bezel
Remove rear bezel from unit.
2
Filter Bracket Screws
Remove filter bracket screws. Pull
filter bracket toward front of unit
until gas/air supply fitting is past
rear panel,
and
swing
filter
assembly out to the side to allow
filter cup removal.
3
Filter Base
4
Filter Element
(Part No. 227877)
5
Filter Cup
Unscrew filter cup from base.
Remove cup.
Unscrew filter element from base.
Check filter element for dirt and
moisture, and replace if necessary.
Be sure that all parts are clean and
dry.
Reinstall filter element, and secure
filter cup.
Secure filter bracket to rear panel.
Reinstall wrapper and rear bezel.