2-8. 115 Volts AC Duplex Receptacle

2-9. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose – no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
1
1
Circuit Breaker
, Time-Delay
3
Normal Operating
200
105
2
125
150
4
116
(35)
6
Y Turn Off power before con-
necting to receptacle.
1
115 V AC Receptacle
Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 4-2).
Power output is shared between
this receptacle and the Remote 14
receptacle (see Section 2-7).
802 933
60 Hz
230
460
575
91
45
36
110
50
45
125
70
50
6
8
10
103
273
286
(31)
(83)
(87)
6
8
10
OM-322 Page 13