Drive Self Test (Dst) - Seagate ST9900805SS Product Manual

Standard, self-encrypting drive & sed fips 140-2 models
Hide thumbs Also See for ST9900805SS:
Table of Contents

Advertisement

The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the specified limit in
compliance with the SCSI standard. The drive temperature is reported in the FRU code field of mode sense data. You can
use this information to determine if the warning is due to the temperature exceeding the drive threatening temperature or the
user-specified temperature.
This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the Method of
Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).
The current algorithm implements two temperature trip points. The first trip point is set at 68°C. The second trip point is user-
selectable using the Log Select command. The reference temperature parameter in the temperature log page (see Table 1)
can be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of
0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense
code is sent to the host to indicate the rounding of the parameter field.
Table 1 Temperature Log Page (0Dh)
Parameter Code
Description
Primary Temperature
0000h
Reference Temperature
0001h
5.2.6

Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST
validates the functionality of the drive at a system level.
There are two test coverage options implemented in DST:
1. Extended test
2. Short test
The most thorough option is the extended test that performs various tests on the drive and scans every logical block address
(LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does
some fundamental tests and scans portions of the media.
If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from
service and return it to Seagate for service.
5.2.6.1
DST failure definition
The drive will present a "diagnostic failed" condition through the self-tests results value of the diagnostic log page if a
functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more
stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data
is recoverable, no failure condition will be reported regardless of the number of retries required to recover the data.
The following conditions are considered DST failure conditions:
• Seek error after retries are exhausted
• Track-follow error after retries are exhausted
• Read error after retries are exhausted
• Write error after retries are exhausted
Recovered errors will not be reported as diagnostic failures.
S
10K.5 SAS P
AVVIO
RODUCT
M
, R
. J
ANUAL
EV
16

Advertisement

Table of Contents
loading

Table of Contents