Product Manual Momentus 5400.2 Blade ® Server ST9120821AB ST9100824AB ST98823AB ST96812AB ST94813AB 100367617 Rev. B August 2007...
Page 2
SeaBOARD, SeaFONE, SeaTDD, and SeaTools are either trademarks or registered trade- marks of Seagate Technology LLC or one of its affiliated companies in the United States and/ or other countries. All other trademarks or registered trademarks are the property of their respective owners.
Introduction ® This manual describes the functional, mechanical and interface specifications for the following Seagate ® Momentus 5400.2 Blade Server drives: • ST9120821AB • ST9100824AB • ST98823AB • ST96812AB • ST94813AB These drives provide the following key features: • 5,400-RPM spindle speed and 8-Mbyte buffer combine for superior performance.
Page 8
Momentus 5400.2 Blade Server Product Manual, Rev. B...
Average latency (msec) Power-on to ready (sec typical) Standby to ready (sec typical) Startup current 5V (typical) 1.0 amps Track-to-track seek time 1.0 (read), 1.5 (write) (msec typical) Average seek time (msec typical) 12.5 Momentus 5400.2 Blade Server Product Manual, Rev. B...
Page 10
20,000 hard power on/off cycles 32°C, 80% relative humidity 600,000 software-controlled power on/off cycles 5°C, 80% relative humidity 20,000 hard power on/off cycles 5°C, 10% relative humidity 55°C, 16% relative humidity Service life 5 Years Momentus 5400.2 Blade Server Product Manual, Rev. B...
When addressing these drives in LBA mode, all blocks (sectors) are consecutively numbered from 0 to n–1, where n is the number of guaranteed sectors as defined above. Physical organization Model Read/write heads Number of discs ST9120821AB ST9100824AB ST98823AB ST96812AB ST94813AB Momentus 5400.2 Blade Server Product Manual, Rev. B...
Idle, low power mode* 0.80 Standby 0.26 Sleep 0.26 *During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels. Momentus 5400.2 Blade Server Product Manual, Rev. B...
10 MHz. Note. Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write current. 2.9.3 Voltage tolerance Voltage tolerance (including noise): 5V ± 5% Momentus 5400.2 Blade Server Product Manual, Rev. B...
Operating 30°C (86°F max) Nonoperating 40°C (104°F max) 2.10.4 Altitude Operating –304.8 m to 3,048 m (–1,000 ft to 10,000 ft) Nonoperating –304.8 m to 12,192 m (–1,000 ft to 40,000 ft) Momentus 5400.2 Blade Server Product Manual, Rev. B...
The following table lists the maximum nonoperating vibration that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation. 5–500 Hz 5.0 Gs (0 to peak). Max displacement may apply below 22 Hz. Momentus 5400.2 Blade Server Product Manual, Rev. B...
A - 1) No upset or degradation in performance beyond manufacturer’s specified limits. 2) No data loss. B - 1) Unit self recovers without user intervention. 2) No data loss. C - 1) Upset OK provided that unit will function after user intervention. Momentus 5400.2 Blade Server Product Manual, Rev. B...
Information Technology Equipment (ITE). Emission levels are defined by EN 55022, Class B and the immunity levels are defined by EN 55024. Seagate uses an independent laboratory to confirm compliance with the EC directives specified in the previous paragraph. Drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the directives when used in the test systems, we cannot guarantee that all systems will comply with the directives.
As a subassembly, no Federal Communications Commission verification or certification of the device is required. Seagate Technology LLC has tested this device in enclosures as described above to ensure that the total assembly (enclosure, disc drive, motherboard, power supply, etc.) does comply with the limits for a Class B computing device, pursuant to Subpart J, Part 15 of the FCC rules.
Lead (Pb), in electronic products effective July 2006. A number of parts and materials in Seagate products are procured from external suppliers. We rely on the rep-resentations of our suppliers regarding the presence of RoHS substances in these parts and materials. Our...
Page 22
Momentus 5400.2 Blade Server Product Manual, Rev. B...
• Do not remove the factory-installed labels from the drive or cover them with additional labels. Removal voids the warranty. Some factory-installed labels contain information needed to service the drive. Other labels are used to seal out dirt and contamination. Momentus 5400.2 Blade Server Product Manual, Rev. B...
CSEL, on the interface bus. Master and slave drives are determined by their physical position on the cable. To enable cable select, set a jumper as shown in Figure 3. Refer to your computer manual to determine whether your computer supports this option. Momentus 5400.2 Blade Server Product Manual, Rev. B...
0.148 ±.010 X 90 2 .152 .399 DETAIL A (PATA) 2.430 .039 B C D .016 2 .012 .370 .160 DETAIL A DETAIL A (SATA) Figure 4. Mounting dimensions—top, side and end view Momentus 5400.2 Blade Server Product Manual, Rev. B...
Page 26
Momentus 5400.2 Blade Server Product Manual, Rev. B...
Words 54–58, 64–70 and 88 are valid 0007 Number of current logical cylinders xxxx Number of current logical heads xxxx Number of current logical sectors per logical track xxxx 57–58 Current capacity in sectors xxxx Momentus 5400.2 Blade Server Product Manual, Rev. B...
Page 32
Advanced power management value 0040 Master password revision code FFFE Hardware reset value (see description following this table) xxxx Auto acoustic management setting xxxx 95–127 ATA-reserved 0000 Security status 0001 129–159 Seagate-reserved xxxx Momentus 5400.2 Blade Server Product Manual, Rev. B...
Page 33
Ultra DMA mode 4 is currently active. Ultra DMA mode 5 is currently active. Word 93 1 = 80-conductor cable detected, CBLID above V 0 = 40-conductor cable detected, CBLID below V Momentus 5400.2 Blade Server Product Manual, Rev. B...
Disable write cache. Enable read look-ahead (read cache) feature (default). Report full capacity available Note. At power-on or after a hardware or software reset the default values of the features are as indicated above. Momentus 5400.2 Blade Server Product Manual, Rev. B...
+1-405-324-4770. Seagate Service Centers Presales Support Our Presales Support staff can help you determine which Seagate products are best suited for your specific application or computer system, as well as drive availability and compatibility. Technical Support If you need help installing your drive, consult your system's documentation or contact the dealer's support ser- vices department for assistance specific to your system.
Page 36
Data Recovery Services Seagate offers data recovery services for all formats and all brands of storage media. Our Data Recovery Ser- vices labs are currently located in North America. To get a free quick quote or speak with a case management representative, call 1-800-475-0143.
Page 37
European support services For presales and technical support in Europe, dial the Seagate Service Center toll-free number for your spe- cific location. If your location is not listed here, dial our presales and technical support call center at +1-405- 324-4714 from 8:00 .
Page 38
Hours of operation are 8:30 to 5:30 Monday through Friday (Australian Western time). Hours of operation are 9:00 to 6:00 Monday through Saturday. Hours of operation are 9:30 to 6:30 Monday through Friday. Authorized Service Center Momentus 5400.2 Blade Server Product Manual, Rev. B...
Page 39
We are interested in your comments and suggestions regarding this publication. Please take a few minutes to participate in our survey at the following URL: http://survey.seagate.com/survey/techpubs.nsf Thank you for your time and comments. Momentus 5400.2 Blade Server Product Manual, Rev. B...
Page 40
Momentus 5400.2 Blade Server Product Manual, Rev. B...
Page 41
Idle Immediate 23 data-transfer rates 1 Idle mode power 8 DC power 8 IEC950 13 density 6 Information Technology Equipment 13 Diagnostic Defense 1 Initialize Device Parameters 22 diagnostic software 1 interface 6 Momentus 5400.2 Blade Server Product Manual, Rev. B...
Page 42
8 servo electronics 8 power-management commands 23 Set Features 23 power-management modes 10 Set Features command 28 Power-on to Ready 7 Set Max 23 precautions 19 Set Multiple Mode 23 Momentus 5400.2 Blade Server Product Manual, Rev. B...