Mitsubishi Electric PCA-A24GA Service Manual page 24

Pca series ceiling suspended split-type, heat pump air conditioners split-type, air conditioners
Hide thumbs Also See for PCA-A24GA:
Table of Contents

Advertisement

10-6-2. Indoor controller board
PCA-A24GA
PCA-A30GA
PCA-A24GA
PCA-A30GA
1
CN2D
Connect to the indoor
power board (CN2S)
(12.5~13.7V DC)
CN3C
Transmission
(Indoor/outdoor)
(0~24V DC)
CNDK
Connect to the indoor
power board (CNSK)
(208/230V AC)
FUSE
(6.3 A 250 V)
CND
Power supply input
(208/230V AC)
CNP
Drain-pump output
(DP)
(208/230V AC)
SWE
Emergency operation
FAN
Fan motor output
PCA-A36GA
PCA-A36GA
1
1
LED1
Power supply (I.B)
Jumper wire J41, J42
Pair number setting with
wireless remote controller
PCA-A42GA
PCA-A42GA
1
LED2
LED3
Power supply (R.B)
Transmission (Indoor/outdoor)
SW2
SW1
Capacity setting
Model setting
24
CN22
Connect to the terminal
block(TB5)
(Remote controller connecting
wire)
(10.4~14.6V DC)
CN20
Room temperature
thermistor (TH1)
CN21
Pipe temperature
thermistor/Liquid (TH2)
CN29
Condenser/evaporator
temperature thermistor (TH5)
CN31
Drain sensor (DS)
CN90
Connect to the wireless
remote controller board
(CNB)
CN6V
Vane motor output
(MV)
CN41
Connector (HA terminal-A)
CN51
Centrally control
CN24
Heater output
(12V DC)
CN32
Remote switch
CN2L
Connector
(LOSSNAY)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents