Step 3—Measure & Connect Primary Power
The DC input power to the transceiver must be within 10–30 Vdc and
capable of continuously providing at least 2.5 Amperes. A power con-
nector with screw-terminals is provided with each unit. Strip the wire
leads to 6 mm (1/4 inch). Be sure to observe proper polarity as shown
in
Figure 2
with the positive lead ( + ) on the left side; negative on the
right side.
CAUTION
POSSIBLE
EQUIPMENT
DAMAGE
Typically, it takes about 30 seconds for the transceiver to fully
NOTE:
power up, and may take several minutes to associate with
another unit, especially if GPS is required for time synchroni-
zation.
Step 4—Review the Transceiver's Configuration
There are two key settings that must be known before placing the unit
into service:
Network Name
are part of the same network. The Network Name must be pro-
grammed to enable Remote units to associate with the Access
Point unit. (Default name is
IP Address
through the
4
MDS Mercury Series Startup Guide
Figure 2. Power Connector
(Polarity: Left +, Right –)
The transceiver must be used with negative-ground sys-
tems only. The power supply should be equipped with
overload protection (NEC Class 2 rating), to protect
against a short circuit between its output terminals and
the radio's power connector.
— Common identifier used by all of the units, that
—Must be a unique address to allow for IP access
port or over-the-air. (Default is
LAN
Invisible place holder
.)
MDS-Mercury
)
192.168.1.1
05-4558A01, Rev. C