Error mode display
LED1
LED2
Power
Inspection
(Motor lock)
LED1
LED2
Power
Inspection
(Overvoltage, low voltage,
power supply frequency
detection)
LED1
LED2
Power
Inspection
(Microcomputer RAM abnormality)
LED1
LED2
Power
Inspection
(Overcurrent detection)
LED1
LED2
Power
Inspection
(Current detection circuit
abnormality)
Cause
1.Motor
2.Control circuit
1.Excess voltage applied
2.Low voltage
3.No power supply
frequency
4.Control circuit
1.Control circuit
1.Motor
2.Control circuit
1.Control circuit
Check procedure and action to take
• Measure the winding resistance. (Measure the
resistance values between "black and white," "red and
black," and "white and red" wires of the 1-pin
connector coming from the motor.)
* Replace the motor if the measured values are other
than the normal value shown in
the table at right.
• Replace the control circuit if other than above.
• Is a rated power supply voltage of 220 to 240 V being
applied?
• Is a rated power supply voltage of 220 to 240 V being
applied?
• Is a power supply frequency 50 or 60 Hz?
• Replace the control circuit if other than the above.
• Replace the control circuit.
• Measure the winding resistance. (Measure the
resistance values between "black and white," "red and
black," and "white and red" wires of the 1-pin
connector coming from the motor.)
* Replace the motor if the measured values are other
than the normal value shown
in the table at right.
• Replace the control circuit if other than above.
• Replace the control circuit.
— 10 —
Measured value
Decision
Approx. 3.4 to 3.7Ω
Normal
Measured value
Decision
Approx. 3.4 to 3.7Ω
Normal